Page 6

Environmental Specifications

Parameter

Min

Typ

Max

Units

Notes

Ambient Temperature

-10

7

70

°C

Derated above 50C

Storage Temperature

-40

85

°C

Operating Altitude

2250/7382

m/ft

Non-operating Altitude

8200/30k

m / ft

Power Derating with Temperature

2.5

%/°C

50C to 70C

Power Derating with Altitude

2.0

C/301 m

C/1000 ft

Above 2250 m/7382 ft

Acoustic noise

55

dbA

25C, half load

Over Temperature Protection

110/95

°C

Shutdown / restart

Humidity
Operating

Storage

30
10

95
95

%

Relative humidity, non-condensing

Shock and Vibration acceleration

6

Grms

NEBS GR-63-CORE, Level 3, 20 -
2000Hz, min 30 minutes

Earthquake Rating

4

Zone

NEBS GR-63-CORE, all floors, Seismic

Zone 4 Designed and tested to meet
NEBS specifications.


EMC Compliance

Parameter

Criteria

Standard

Level

Test

DC input

Conducted emissions

EN55022, FCC Docket 20780 part 15,
subpart J

A

8

0.15

30MHz

Radiated emissions

9

EN55022

A 30

10000MHz

DC INPUT
immunity

Voltage dips

EN61000-4-11

B

-30%, 10ms

B -60%,

100ms

B -100%,

5sec

Voltage surge

EN61000-4-5, level 4

A

4kV, 1.2/50µs, common mode

A

2kV, 1.2/50µs, differential
mode

Fast transients

EN61000-4-4, level 3

B

5/50ns, 2kV (common mode)

Enclosure
immunity

Conducted RF fields

EN61000-4-6, level 3

A

130dBµV, 0.15-80MHz, 80%
AM

Radiated RF fields

EN61000-4-3, level 3

A

10V/m, 80-1000MHz, 80% AM

ENV50140 A

ESD

EN61000-4-2, level 3

B

6kV contact, 8kV air

7

Designed to start at an ambient down to -40°C; meet spec after  30 min warm up period, may not meet operational limits below -10°C.

8

Class B EMI conducted and radiated levels met with an external filter. Please contact sales for a recommended filter.

9

Radiated emissions compliance is contingent upon the final system configuration.