Output, Emc considerations – GE Industrial Solutions ESTW006A0B Series User Manual
Page 12
Advertising
Data Sheet
November 5, 2012
ESTW006A0B Series Eighth-Brick Power Modules
36 - 75Vdc Input; 12V/6A
dc
Output
LINEAGE
POWER
12
EMC Considerations
The circuit and plots in Figure 26 shows a suggested configuration to meet the conducted emission limits of EN55022
Class B.
Figure 26. EMC Considerations.
For further information on designing for EMC compliance, please refer to the FLT007A0 data sheet (DS05-028).
V
IN
= 48V, Io = I
o,max
, L Line
Blue= Quasi-peak, Red = Avg
V
IN
= 48V, Io = I
o,max
, N Line
Blue= Quasi-peak, Red = Avg