Output, Emc considerations – GE Industrial Solutions ESTW006A0B Series User Manual

Page 12

Advertising
background image

Data Sheet
November 5, 2012

ESTW006A0B Series Eighth-Brick Power Modules

36 - 75Vdc Input; 12V/6A

dc

Output

LINEAGE

POWER

12

EMC Considerations

The circuit and plots in Figure 26 shows a suggested configuration to meet the conducted emission limits of EN55022
Class B.

Figure 26. EMC Considerations.

For further information on designing for EMC compliance, please refer to the FLT007A0 data sheet (DS05-028).

V

IN

= 48V, Io = I

o,max

, L Line

Blue= Quasi-peak, Red = Avg

V

IN

= 48V, Io = I

o,max

, N Line

Blue= Quasi-peak, Red = Avg