12v austin superlynx, 16a: non-isolated dc-dc power modules, Data sheet – GE Industrial Solutions 12V Austin SuperLynx 16A User Manual

Page 5: Feature specifications

Advertising
background image

GE

Data Sheet

12V Austin SuperLynx

TM

16A: Non-Isolated DC-DC Power Modules

10Vdc –14Vdc input; 0.75Vdc to 5.5Vdc output; 16A Output Current

May 7, 2013

©2013 General Electric Company. All rights reserved.

Page 5

Feature Specifications

Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See
Feature Descriptions for additional information.

Parameter

Device

Symbol

Min

Typ

Max

Unit

Remote On/Off Signal interface

(V

IN

=V

IN, min

to V

IN, max

; Open collector npn or equivalent

Compatible, Von/off signal referenced to GND

See feature description section)

Logic High (On/Off Voltage pin open - Module ON)

Von/Off

All

V

IH

— — V

IN

V

Ion/Off

All

I

IH

— — 10 μA

Logic Low (Von/Off

≤ 0.3V – Module OFF)

Von/Off

All

V

IL

— — 0.3

V

Ion/off

All

I

IL

— — 1 mA

Turn-On Delay and Rise Times

(I

O

=I

O, max ,

V

IN

= V

IN, nom,

T

A

= 25

o

C, )

Case 1: On/Off input is set to Logic Low (Module
ON) and then input power is applied (delay from

instant at which V

IN

=V

IN, min

until Vo=10% of Vo,set)

All Tdelay —

3

msec

Case 2: Input power is applied for at least one second

and then the On/Off input is set to logic Low (delay from
instant at which Von/Off=0.3V until Vo=10% of Vo, set)

All Tdelay —

3

msec

Output voltage Rise time (time for Vo to rise from 10%
of V

o,set

to 90% of Vo, set)

All Trise

— 4 6 msec

Output voltage overshoot – Startup

1

% V

O, set

I

O

= I

O, max

; V

IN

= 3.0 to 5.5Vdc, T

A

= 25

o

C

Remote Sense Range

0.5

Overtemperature Protection

All T

ref

125

°C

(See Thermal Consideration section)

Input Undervoltage Lockout

Turn-on Threshold

All

8.2

V

Turn-off Threshold

All

8.0

V









Advertising