12v austin microlynx, 5a: non-isolated dc-dc power modules, Data sheet – GE Industrial Solutions 12V Austin MicroLynx 5A User Manual

Page 4: Electrical specifications, General specifications

Advertising
background image

GE

Data Sheet

12V Austin MicroLynx

TM

5A: Non-Isolated DC-DC Power Modules

10Vdc –14Vdc input; 0.75Vdc to 5.5Vdc output; 5A Output Current

May 6, 2013

©2013 General Electric Company. All rights reserved.

Page 4

Electrical Specifications

(continued)

Parameter

Device

Symbol

Min

Typ

Max

Unit

Dynamic Load Response

(dIo/dt=2.5A/

μs; V V

IN

= V

IN, nom

; T

A

=25°C)

All V

pk

50

mV

Load Change from Io= 50% to 100% of Io,max;

Co = 2x150 μF polymer capacitors

Peak Deviation

Settling Time (Vo<10% peak deviation)

All t

s

50

μs

(dIo/dt=2.5A/

μs; V

IN

= V

IN, nom

; T

A

=25°C)

All V

pk

50

mV

Load Change from Io= 100% to 50%of Io,max:
Co = 2x150 μF polymer capacitors

Peak Deviation

Settling Time (Vo<10% peak deviation)

All t

s

50

μs

General Specifications

Parameter

Min

Typ

Max

Unit

Calculated MTBF (I

O

=I

O, max

, T

A

=25°C) 5,677,000

Hours

Weight

2.8 (0.1)

g (oz.)


















Advertising