GE Industrial Solutions PicoTLynx 6A User Manual

Picotlynx, 6a: non-isolated dc-dc power modules, Data sheet

Advertising
background image

GE

Data Sheet

September 11, 2013

©2013 General Electric Company. All rights reserved.

PicoTLynx

TM

6A: Non-Isolated DC-DC Power Modules

2.4Vdc –5.5Vdc input; 0.6Vdc to 3.63Vdc output; 6A Output Current

Features

Compliant to RoHS EU Directive 2002/95/EC (Z versions)

Compatible in a Pb-free or SnPb reflow environment (Z
versions)

Wide Input voltage range (2.4Vdc-5.5Vdc)

Output voltage programmable from 0.6Vdc to 3.63 Vdc
via external resistor

Tunable Loop

TM

to optimize dynamic output voltage

response

Flexible output voltage sequencing EZ-SEQUENCE –

APTH versions

Remote sense

Fixed switching frequency

Output overcurrent protection (non-latching)

Overtemperature protection

Cost efficient open frame design

Remote On/Off

Ability to sink and source current

Small size:

12.2 mm x 12.2 mm x 7.25 mm
(0.48 in x 0.48 in x 0.29 in)

Wide operating temperature range (-40°C to

85°C)

UL* 60950-1Recognized, CSA

C22.2 No. 60950-1-03

Certified, and VDE

0805:2001-12 (EN60950-1) Licensed

ISO** 9001 and ISO 14001 certified manufacturing
facilities

Applications

Distributed power architectures

Intermediate bus voltage applications

Telecommunications equipment

Servers and storage applications

Networking equipment

Industrial Equipment

Description

The Pico TLynx

TM

6A power modules are non-isolated dc-dc converters that can deliver up to 6A of output current. These modules

operate over a wide range of input voltage (V

IN

= 2.4Vdc-5.5Vdc) and provide a precisely regulated output voltage from 0.6Vdc to

3.63Vdc, programmable via an external resistor. Features include remote On/Off, adjustable output voltage, over current and

overtemperature protection, and output voltage sequencing (APTH versions). A new feature, the Tunable Loop

TM

, allows the user

to optimize the dynamic response of the converter to match the load with reduced amount of output capacitance leading to
savings on cost and PWB area.

*

UL is a registered trademark of Underwriters Laboratories, Inc.

CSA is a registered trademark of Canadian Standards Association.

VDE is a trademark of Verband Deutscher Elektrotechniker e.V.

** ISO is a registered trademark of the International Organization of Standards


TRIM

VOUT

SENSE

GND

CTUNE

RTUNE

RTrim

VIN

Co

Cin

Vin+

Vout+

ON/OFF

Q1

SEQ

MODULE

RoHS Compliant

EZ-SEQUENCE

TM

Advertising