Picotlynx, 6a: non-isolated dc-dc power modules, Data sheet – GE Industrial Solutions PicoTLynx 6A User Manual

Page 17: Thermal considerations

Advertising
background image

GE

Data Sheet

PicoTLynx

TM

6A: Non-Isolated DC-DC Power Modules

2.4Vdc –5.5Vdc input; 0.6Vdc to 3.63Vdc output; 6A Output Current

September 11, 2013

©2013 General Electric Company. All rights reserved.

Page 17

Thermal Considerations

Power modules operate in a variety of thermal environments;
however, sufficient cooling should always be provided to help
ensure reliable operation.

Considerations include ambient temperature, airflow, module
power dissipation, and the need for increased reliability. A
reduction in the operating temperature of the module will result
in an increase in reliability. The thermal data presented here is
based on physical measurements taken in a wind tunnel. The
test set-up is shown in Figure 45. The preferred airflow

direction for the module is in Figure 46.

Air

flow

x

Power Module

Wind Tunnel

PWBs

12.7_

(0.50)

76.2_

(3.0)

Probe Location
for measuring
airflow and
ambient

temperature

25.4_

(1.0)

Figure 45. Thermal Test Setup.

The thermal reference points, T

ref

used in the specifications are

also shown in Figure 43. For reliable operation the temperatures

at these points should not exceed 125

o

C. The output power of

the module should not exceed the rated power of the module
(Vo,set x Io,max).

Please refer to the Application Note “Thermal Characterization
Process For Open-Frame Board-Mounted Power Modules” for a
detailed discussion of thermal aspects including maximum
device temperatures.

Figure 46. Preferred airflow direction and location of hot-spot

of the module (Tref).

Advertising