General Specifications

Parameter

Min

Typ

Max

Unit

Calculated Reliability based upon Telcordia SR-332 Issue 2: Method

I

Case 3

(V

IN

=24V

dc

, I

O

=80%xI

O, max

, T

A

=40°C, airflow = 200 LFM, 90% confidence)

FIT >=176.9

10

9

/Hours

MTBF >=5,652,118 Hours

Weight

8 (0.28)

g (oz.)

Feature Specifications

Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See
Feature Descriptions for additional information.

Parameter

Device

Symbol

Min

Typ

Max

Unit

Remote On/Off Signal Interface

(V

IN

=V

IN, min

to V

IN, max

; open collector or equivalent,

Signal referenced to V

IN-

terminal)

Negative Logic: device code suffix “1”

Logic Low = module On, Logic High = module Off

Logic Low - Remote On/Off Current (V

on/off

= -0.7V

dc

) All

I

on/off

0.15 mA

Logic Low - On/Off Voltage

All

V

on/off

-0.7

0.8 V

dc

Logic High Voltage (I

on/off

= 0A

dc

) All

V

on/off

2.0

V

IN

V

dc

Logic High maximum allowable leakage current

All

I

on/off

25

μA

Positive Logic: No device code suffix required

Logic Low = module Off, Logic High = module On

Logic Low - Remote On/Off Current (V

on/off

= -0.7V

dc

) All

I

on/off

0.15 mA

Logic Low - On/Off Voltage

All

V

on/off

-0.7

0.8 V

dc

Logic High Voltage (I

on/off

= 0A

dc

) All

V

on/off

2.0

V

IN

V

dc

Logic High maximum allowable leakage current

All

I

on/off

25

μA

Turn-On Delay and Rise Times for each output

(I

O

=80% of I

O, max

, T

A

=25°C)

Case 1: Input power is applied for at least 1second, and then the

On/Off input is set from OFF to ON (T

delay

= on/off pin transition until

V

O

= 10% of V

O, set

)

All

T

delay

Case1

25 ms

Case 2: On/Off input is set to Module ON, and then input power is

applied (T

delay

= V

IN

reaches V

IN, min

until V

O

= 10% of V

O,set

)

All

T

delay

Case2

25 ms

Output voltage Rise time (time for V

o

to rise from 10%

of V

o,set

to 90% of V

o, set

)

All T

rise

25 ms

Output Voltage Overshoot

3 %

V

O, set

(I

O

=80% of I

O, max

, V

IN

= 9 to 36V

dc

, T

A

=25°C)

Output Overvoltage Protection

All V

O, limit

140 %V

01,o2

Input Undervoltage Lockout

Turn-on Threshold

All

V

uv/on

8.5 V

dc

Turn-off Threshold

All

V

uv/off

7.5

V

dc

Hysteresis All

V

hyst

1.0 V

dc

Advertising