Shhn000a3 series; dc-dc converter power modules, Datasheet, Test configurations – GE Industrial Solutions SHHN000A3 HAMMERHEAD Series User Manual

Page 6: Design considerations, Safety considerations, Input source impedance, Figure 7. input current versus input voltage, Figure 9. output ripple and noise test setup

Advertising
background image

GE

Datasheet

SHHN000A3 Series; DC-DC Converter Power Modules

9Vdc – 36Vdc input; +15V, -15V Dual Output, 0.3A 9W Output

December 6, 2013

©2013 General Electric Corporation.

All rights reserved.

Page 6

Figure 7. Input Current versus Input Voltage

Test Configurations

TO OSCILLOSCOPE

CURRENT PROBE

L

TEST

12μH

BA

T

T

E

R

Y

C

S

220μF

E.S.R.<0.1

Ω

@ 20°C 100kHz

33μF

Vin+

Vin-

NOTE: Measure input reflected ripple current with a simulated

source inductance (L

TEST

) of 12μH. Capacitor C

S

offsets

possible battery impedance. Measure current as shown
above.

Figure 8. Input Reflected Ripple Current Test Setup.

NOTE: All voltage measurements to be taken at the module

terminals, as shown above. If sockets are used then
Kelvin connections are required at the module terminals
to avoid measurement errors due to socket contact
resistance.

V

O

(+)

V

O

(

)

1uF

.

RESISTIVE

LOAD

SCOPE

COPPER STRIP

GROUND PLANE

10uF

Figure 9. Output Ripple and Noise Test Setup.

Vout+

Vout-

Vin+

Vin-

R

LOAD

R

contact

R

distribution

R

contact

R

distribution

R

contact

R

contact

R

distribution

R

distribution

V

IN

V

O

NOTE: All voltage measurements to be taken at the module

terminals, as shown above. If sockets are used then
Kelvin connections are required at the module terminals
to avoid measurement errors due to socket contact
resistance.

Figure 10. Output Voltage and Efficiency Test Setup.

η =

V

O

. I

O

V

IN

. I

IN

x

100

%

Efficiency



Design Considerations

Input Source Impedance

The power module shall be connected to a low ac-impedance
source. Highly inductive source impedance can affect the

stability of the power module. For the test configuration in
Figure 8, a 33μF electrolytic capacitor (ESR<0.7

Ω at 100kHz),

mounted close to the power module helps ensure the stability
of the unit

Safety Considerations

For safety-agency approval of the system in which the power

module is used, the power module shall be installed in
compliance with the spacing and separation requirements of

the end-use safety agency standard, i.e., UL 60950-1-3, CSA
C22.2 No. 60950-00, and VDE 0805 (IEC60950, 3

rd

Edition).

The input to these units is to be provided with a maximum 3A

fast-acting fuse in the ungrounded lead.








0

0.2

0.4

0.6

0.8

1

1.2

1.4

1.6

7

12

17

22

27

32

Input Curr

ent (A

)

Input Voltage (V)

Io min: 0A

Io mid: 0.15A

Io max: 0.3A