12a digital slimlynx, Non-isolated dc-dc power modules, Preliminary data sheet – GE Industrial Solutions 12A Digital SlimLynx User Manual

Page 24

Advertising
background image

GE

Preliminary Data Sheet

12A Digital SlimLynx

TM

: Non-Isolated DC-DC Power Modules

3Vdc –14.4Vdc input; 0.45Vdc to 5.5Vdc output; 12A Output Current

February 19, 2014

©2014 General Electric Company. All rights reserved.

Page 24



STATUS_VOUT : Returns one byte of information relating to
the status of the module’s output voltage related faults.

Bit

Position

Flag

Default

Value

7 VOUT

OV

Fault 0

6 X 0
5 X 0
4

VOUT UV Fault

0

3 X 0
2 X 0
1 X 0
0 X 0

STATUS_IOUT : Returns one byte of information relating to
the status of the module’s output voltage related faults.

Bit

Position

Flag

Default

Value

7

IOUT OC Fault

0

6 X 0
5 IOUT

OC

Warning 0

4 X 0
3 X 0
2 X 0
1 X 0
0 X 0

STATUS_TEMPERATURE : Returns one byte of information

relating to the status of the module’s temperature related
faults.

Bit

Position

Flag

Default

Value

7 OT

Fault 0

6 OT

Warning 0

5 X 0
4 X 0
3 X 0
2 X 0
1 X 0
0 X 0

STATUS_CML : Returns one byte of information relating to the
status of the module’s communication related faults.

Bit

Position

Flag

Default

Value

7 Invalid/Unsupported

Command 0

6 Invalid/Unsupported

Command 0

5

Packet Error Check Failed

0

4 X 0
3 X 0
2 X 0
1

Other Communication Fault

0

0 X 0

MFR_VIN_MIN : Returns minimum input voltage as two data
bytes of information in Linear format (upper five bits are

exponent – fixed at -2, and lower 11 bits are mantissa in
two’s complement format – fixed at 12)


MFR_VOUT_MIN : Returns minimum output voltage as two
data bytes of information in Linear format (upper five bits
are exponent – fixed at -10, and lower 11 bits are mantissa
in two’s complement format – fixed at 614)

MFR_SPECIFIC_00 : Returns information related to the type
of module and revision number. Bits [7:2] in the Low Byte
indicate the module type (000000 corresponds to the
ULDT012 series of module), while bits [7:3] indicate the

revision number of the module.

Low Byte

Bit

Position

Flag

Default

Value

7:2 Module

Name 000001

1:0 Reserved 10

High Byte

Bit

Position

Flag

Default

Value

7:3

Module Revision Number

None

2:0 Reserved 000


Advertising