background image

GE

Preliminary Data Sheet

12A Digital SlimLynx

TM

: Non-Isolated DC-DC Power Modules

3Vdc –14.4Vdc input; 0.45Vdc to 5.5Vdc output; 12A Output Current

February 19, 2014

©2014 General Electric Company. All rights reserved.

Page 26



Table 6 (continued)

Hex

Code

Command

Brief Description

Non-Volatile

Memory Storage

22 VOUT_TRIM

Apply a fixed offset voltage to the output voltage command value. Exponent is

fixed at -10. The offset is VOUT_TRIMx2

-10

Format

Linear, two’s complement binary

Bit Position

7 6 5 4 3 2 1 0

Access

r/w r/w r/w

r/w

r/w

r/w

r/w r/w

Function

High Byte

Default Value

0 0 0 0 0 0 0 0

Bit Position

7 6 5 4 3 2 1 0

Access

r/w r/w r/w

r/w

r/w

r/w

r/w r/w

Function

Low Byte

Default Value

0 0 0 0 0 0 0 0

YES

25 VOUT_MARGIN_HIGH

Sets the target voltage for margining the output high. Exponent is fixed at -10.
The offset is (VOUT_MARGIN_HIGH+VOUT_TRIM)x2

-10

Format

Linear, two’s complement binary

Bit Position

7 6 5 4 3 2 1 0

Access

r r/w r/w

r/w

r/w

r/w

r/w r/w

Function

High Byte

Default Value

0 0 0 0 0 1 0 1

Bit Position

7 6 5 4 3 2 1 0

Access

r/w r/w r/w

r/w

r/w

r/w

r/w r/w

Function

Low Byte

Default Value

0 1 0 0 0 1 1 1

YES

26 VOUT_MARGIN_LOW

Sets the target voltage for margining the output low. Exponent is fixed at -10.
The offset is (VOUT_MARGIN_LOW+VOUT_TRIM)x2

-10

Format

Linear, two’s complement binary

Bit Position

7 6 5 4 3 2 1 0

Access

r r/w r/w

r/w

r/w

r/w

r/w r/w

Function

High Byte

Default Value

0 0 0 0 0 1 0 0

Bit Position

7 6 5 4 3 2 1 0

Access

r/w r/w r/w

r/w

r/w

r/w

r/w r/w

Function

Low Byte

Default Value

0 1 0 1 0 0 0 1

YES

29 VOUT_SCALE_LOOP

Sets the scaling of the output voltage – equal to the feedback resistor divider
ratio. VOUT_SCALE_LOOP = 0.6(V)/VOUT(V)

Format

Linear, two’s complement binary

Bit Position

7 6 5 4 3 2 1 0

Access

r r r

r

r

r

r/w r/w

Function

Exponent Mantissa

Default Value

1 0 1 1 1 0 0 1

Bit Position

7 6 5 4 3 2 1 0

Access

r/w r/w r/w

r/w

r/w

r/w

r/w r/w

Function

Mantissa

Default Value

0 0 0 0 0 0 0 0

YES

35 VIN_ON

Sets the value of input voltage at which the module turns on. This must be
higher than VIN_OFF. Supported Values are

2.75V

3V to 18V in increments of 0.5V

Format

Linear, two’s complement binary

Bit Position

7 6 5 4 3 2 1 0

Access

r r r

r

r

r

r r

Function

Exponent Mantissa

Default Value

1 1 1 1 0 0 0 0

Bit Position

7 6 5 4 3 2 1 0

Access

r r/w r/w

r/w

r/w

r/w

r/w r/w

Function

Mantissa

Default Value

0 0 0 0 1 0 1 1

YES

Advertising