12a digital slimlynx, Non-isolated dc-dc power modules, Preliminary data sheet – GE Industrial Solutions 12A Digital SlimLynx User Manual

Page 25: Summary of supported pmbus commands

Advertising
background image

GE

Preliminary Data Sheet

12A Digital SlimLynx

TM

: Non-Isolated DC-DC Power Modules

3Vdc –14.4Vdc input; 0.45Vdc to 5.5Vdc output; 12A Output Current

February 19, 2014

©2014 General Electric Company. All rights reserved.

Page 25


Summary of Supported PMBus Commands

Please refer to the PMBus 1.1 specification for more details of these commands.

Table 6

Hex

Code

Command

Brief Description

Non-Volatile

Memory Storage

01 OPERATION

Turn Module on or off. Also used to margin the output voltage

Format

Unsigned Binary

Bit Position

7 6 5 4 3 2 1 0

Access

r/w r r/w

r/w

r/w

r/w

r r

Function

On X

Margin

X X

Default Value

0 0 0 0 0 0 X X

02 ON_OFF_CONFIG

Configures the ON/OFF functionality as a combination of analog ON/OFF pin

and PMBus commands

Format

Unsigned Binary

Bit Position

7 6 5 4 3 2 1 0

Access

r r r

r/w

r/w

r/w

r/w r

Function

X X X pu

cmd

cpr

pol

cpa

Default Value

0 0 0 1 0 1 1 1

YES

03 CLEAR_FAULTS

Clear any fault bits that may have been set, also releases the SMBALERT# signal
if the device has been asserting it.

10 WRITE_PROTECT

Used to control writing to the module via PMBus. Copies the current register

setting in the module whose command code matches the value in the data byte
into non-volatile memory (EEPROM) on the module

Format

Unsigned Binary

Bit Position

7 6 5 4 3 2 1 0

Access

r/w r/w r/w

x

x

x

x x

Function

bit7

bit6

bit5 X X X X X

Default Value

0 0 0 X X X X X

Bit5: 0 – Enables all writes as permitted in bit6 or bit7
1 – Disables all writes except the WRITE_PROTECT, OPERATION

and ON_OFF_CONFIG (bit 6 and bit7 must be 0)
Bit 6: 0 – Enables all writes as permitted in bit5 or bit7
1 – Disables all writes except for the WRITE_PROTECT and
OPERATION commands (bit5 and bit7 must be 0)

Bit7: 0 – Enables all writes as permitted in bit5 or bit6
1 – Disables all writes except for the WRITE_PROTECT command
(bit5 and bit6 must be 0)

YES

11 STORE_DEFAULT_ALL

Copies all current register settings in the module into non-volatile memory
(EEPROM) on the module. Takes about 50ms for the command to execute.

12 RESTORE_DEFAULT_ALL

Restores all current register settings in the module from values in the module

non-volatile memory (EEPROM)

13 STORE_DEFAULT_CODE

Copies the current register setting in the module whose command code
matches the value in the data byte into non-volatile memory (EEPROM) on the
module

Bit Position

7 6 5 4 3 2 1 0

Access

w w w

w

w

w

w w

Function

Command code

14 RESTORE_DEFAULT_CODE

Restores the current register setting in the module whose command code
matches the value in the data byte from the value in the module non-volatile
memory (EEPROM)

Bit Position

7 6 5 4 3 2 1 0

Access

w w w

w

w

w

w w

Function

Command code

20 VOUT_MODE

The module has MODE set to Linear and Exponent set to -10. These values
cannot be changed

Bit Position

7 6 5 4 3 2 1 0

Access

r r r

r

r

r

r r

Function

Mode Exponent

Default Value

0 0 0 1 0 1 1 0

Advertising