20a digital microdlynx, Non-isolated dc-dc power modules, Data sheet – GE Industrial Solutions 20A Digital MicroDLynx User Manual

Page 27

Advertising
background image

GE

Data Sheet

20A Digital MicroDLynx

TM

: Non-Isolated DC-DC Power Modules

3Vdc –14.4Vdc input; 0.45Vdc to 5.5Vdc output; 20A Output Current

April 24, 2013

©2012 General Electric Company. All rights reserved.

Page 27

Table 6 (continued)

Hex

Code

Command

Brief Description

Non-Volatile

Memory Storage

36

VIN_OFF

Sets the value of input voltage at which the module turns off

Format

Linear, two’s complement binary

Bit Position

7

6

5

4

3

2

1

0

Access

r

r

r

r

r

r

r

r

Function

Exponent

Mantissa

Default Value

1

1

1

1

0

0

0

0

Bit Position

7

6

5

4

3

2

1

0

Access

r

r/w

r/w

r/w

r/w

r/w

r/w

r/w

Function

Mantissa

Default Value

0

0

0

0

1

0

1

0

YES

38

IOUT_CAL_GAIN

Returns the value of the gain correction term used to correct the measured
output current

Format

Linear, two’s complement binary

Bit Position

7

6

5

4

3

2

1

0

Access

r

r

r

r

r

r

r

r/w

Function

Exponent

Mantissa

Default Value

1

0

0

0

1

0

0

V

Bit Position

7

6

5

4

3

2

1

0

Access

r/w

r/w

r/w

r/w

r/w

r/w

r/w

r/w

Function

Mantissa

Default Value

V: Variable based on factory calibration

YES

39

IOUT_CAL_OFFSET

Returns the value of the offset correction term used to correct the measured
output current

Format

Linear, two’s complement binary

Bit Position

7

6

5

4

3

2

1

0

Access

r

r

r

r

r

r/w

r

r

Function

Exponent

Mantissa

Default Value

1

1

1

0

0

V

0

0

Bit Position

7

6

5

4

3

2

1

0

Access

r

r

r/w

r/w

r/w

r/w

r/w

r/w

Function

Mantissa

Default Value

0

0

V: Variable based on factory calibration

YES

40

VOUT_OV_FAULT_LIMIT

Sets the voltage level for an output overvoltage fault

Format

Linear, two’s complement binary

Bit Position

7

6

5

4

3

2

1

0

Access

r

r/w

r/w

r/w

r/w

r/w

r/w

r/w

Function

High Byte

Default Value

0

0

0

0

0

1

0

1

Bit Position

7

6

5

4

3

2

1

0

Access

r/w

r/w

r/w

r/w

r/w

r/w

r/w

r/w

Function

Low Byte

Default Value

0

0

0

0

1

0

1

0

YES

41

VOUT_OV_FAULT_RESPONSE

Instructs the module on what action to take in response to a output overvoltage
fault

Format

Unsigned Binary

Bit Position

7

6

5

4

3

2

1

0

Access

r/w

r/w

r/w

r/w

r/w

r

r

r

Function

RSP

[1]

RSP

[0]

RS[2] RS[1] RS[0]

X

X

X

Default Value

1

1

1

1

1

1

0

0

YES