Data Sheet

20A Digital MicroDLynx

TM

: Non-Isolated DC-DC Power Modules

3Vdc –14.4Vdc input; 0.45Vdc to 5.5Vdc output; 20A Output Current

April 24, 2013

©2012 General Electric Company. All rights reserved.

Page 29

Table 6 (continued)

Hex

Code

Command

Brief Description

Non-Volatile

Memory Storage

5F

POWER_GOOD_OFF

Sets the output voltage level at which the PGOOD pin is de-asserted low

Format

Linear, two’s complement binary

Bit Position

7

6

5

4

3

2

1

0

Access

r

r/w

r/w

r/w

r/w

r/w

r/w

r/w

Function

High Byte

Default Value

0

0

0

0

0

1

0

0

Bit Position

7

6

5

4

3

2

1

0

Access

r/w

r/w

r/w

r/w

r/w

r/w

r/w

r/w

Function

Low Byte

Default Value

0

1

0

1

0

0

1

0

YES

61

TON_RISE

Sets the rise time of the output voltage during startup

Format

Linear, two’s complement binary

Bit Position

7

6

5

4

3

2

1

0

Access

r

r

r

r

r

r

r

r/w

Function

Exponent

Mantissa

Default Value

1

1

1

0

0

0

0

0

Bit Position

7

6

5

4

3

2

1

0

Access

r/w

r/w

r/w

r/w

r/w

r/w

r/w

r/w

Function

Mantissa

Default Value

0

0

1

0

1

0

1

0

YES

78

STATUS_BYTE

Returns one byte of information with a summary of the most critical module
faults

Format

Unsigned Binary

Bit Position

7

6

5

4

3

2

1

0

Access

r

r

r

r

r

r

r

r

Flag

X

OFF

VOUT

_OV

IOUT_

OC

VIN_U

V

TEMP CML

OTHE

R

Default Value

0

0

0

0

0

0

0

0

79

STATUS_WORD

Returns two bytes of information with a summary of the module’s fault/warning
conditions

Format

Unsigned binary

Bit Position

7

6

5

4

3

2

1

0

Access

r

r

r

r

r

r

r

r

Flag

VOUT

IOUT_

OC

X

X

PGOO

D

X

X

X

Default Value

0

0

0

0

0

0

0

0

Bit Position

7

6

5

4

3

2

1

0

Access

r

r

r

r

r

r

r

r

Flag

X

OFF

VOUT

_OV

IOUT_

OC

VIN_U

V

TEMP CML

OTHE

R

Default Value

0

0

0

0

0

0

0

0

7A

STATUS_VOUT

Returns one byte of information with the status of the module’s output voltage
related faults

Format

Unsigned Binary

Bit Position

7

6

5

4

3

2

1

0

Access

r

r

r

r

r

r

r

r

Flag

VOUT_OV

X

X

VOUT_UV

X

X

X

X

Default Value

0

0

0

0

0

0

0

0

7B

STATUS_IOUT

Returns one byte of information with the status of the module’s output current
related faults

Format

Unsigned Binary

Bit Position

7

6

5

4 3

2 1 0

Access

r

r

r

r

r

r

r

r

Flag

IOUT_OC

X IOUT_OC_WARN X X

X X X

Default Value

0

0

0

0 0

0 0 0