GE

Data Sheet

20A Digital MicroDLynx

TM

: Non-Isolated DC-DC Power Modules

3Vdc –14.4Vdc input; 0.45Vdc to 5.5Vdc output; 20A Output Current

April 24, 2013

©2012 General Electric Company. All rights reserved.

Page 37

Recommended Pad Layout

Dimensions are in millimeters and (inches).
Tolerances: x.x mm

0.5 mm (x.xx in.

0.02 in.) [unless otherwise indicated]

x.xx mm

0.25 mm (x.xxx in

0.010 in.)








2

If unused, connect to Ground.

PIN FUNCTION PIN

FUNCTION

1

ON/OFF

10

SYNC

2

2

VIN

11

CLK

3

SEQ

12

DATA

4

GND

13

SMBALERT#

5

TRIM

14

SIG_GND

6

VOUT

15

ADDR1

7

VS+

16

ADDR0

8

VS-

9

PG