GE Industrial Solutions QPW050-060 Series User Manual

Page 16

Advertising
background image

Data Sheet

February 2, 2011

QPW050/060 Series Power Modules; DC-DC converters

36-75Vdc Input; 1.2Vdc to 3.3Vdc Output

LINEAGE

POWER

16


The following figures provide thermal derating characteristics.

O

U

TPUT

CU

R

R

E

N

T

, I

O

(A

)

0

5

10

15

20

25

30

35

40

45

50

25 30 35 40 45 50 55 60 65 70 75 80 85

NATURAL CONVECTION

1.0 m/s (200 ft./min.)

2.0 m/s (400 ft./min.)

O

U

T

P

UT

C

U

RR

E

N

T

, I

O

(A

)

0

10

20

30

40

50

60

25 30 35 40 45 50 55 60 65 70 75 80 85

NATURAL

CONVECTION

1.0 m/s (200 ft./min.)

2.0 m/s (400 ft./min.)

LOCAL AMBIENT TEMPERATURE, T

A

(

C) LOCAL

AMBIENT

TEMPERATURE,

T

A

(

C)

Figure 41. Output Power Derating for QPW050A0F (Vo
= 3.3V) in Longitudinal Orientation with no baseplate;
Airflow Direction From Vin(–) to Vout(--); Vin = 48V.

Figure 44. Output Power Derating for QPW060A0G (Vo
= 2.5V) in Transverse Orientation with no baseplate;
Airflow Direction From Vin(–) to Vin(+); Vin = 48V.

O

U

TP

UT CU

RR

E

N

T

, I

O

(A

)

0

10

20

30

40

50

25 30 35 40 45 50 55 60 65 70 75 80 85

NATURAL CONVECTION

1.0 m/s (200 ft./min.)

2.0 m/s (400 ft./min.)

OUT

P

UT C

URR

EN

T,

I

O

(A

)

0

10

20

30

40

50

60

25 30 35 40 45 50 55 60 65 70 75 80 85

NATURAL

CONVECTION

1.0 m/s (200 ft./min.)

2.0 m/s (400 ft./min.)

LOCAL AMBIENT TEMPERATURE, T

A

(

C) LOCAL

AMBIENT

TEMPERATURE,

T

A

(

C)

Figure 42. Output Power Derating for QPW050A0F (Vo
= 3.3V) in Transverse Orientation with no baseplate;
Airflow Direction From Vin(–) to Vin(+); Vin = 48V.

Figure 45. Output Power Derating for QPW060A0Y (Vo
= 1.8V) in Longitudinal Orientation with no baseplate;
Airflow Direction From Vin(–) to Vout(--); Vin = 48V.

O

U

TPU

T

CUR

RE

NT

, I

O

(A

)

0

10

20

30

40

50

60

25 30 35 40 45 50 55 60 65 70 75 80 85

NATURAL
CONVECTION

1.0 m/s (200 ft/min)

2.0 m/s (400 ft/min)

O

U

TPU

T

CUR

RE

NT

, I

O

(A

)

0

10

20

30

40

50

60

25 30 35 40 45 50 55 60 65 70 75 80 85

NATURAL

CONVECTION

1.0 m/s (200 ft./min.)

2.0 m/s (400 ft./min.)

LOCAL AMBIENT TEMPERATURE, T

A

(

C) LOCAL

AMBIENT

TEMPERATURE,

T

A

(

C)

Figure 43. Output Power Derating for QPW060A0G (Vo
= 2.5V) in Longitudinal Orientation with no baseplate;
Airflow Direction From Vin(–) to Vout(--); Vin = 48V.

Figure 46. Output Power Derating for QPW060A0Y (Vo
= 1.8V) in Transverse Orientation with no baseplate;
Airflow Direction From Vin(–) to Vin(+); Vin = 48V.

Advertising