Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for
extended periods can adversely affect the device reliability.
Parameter
Device
Symbol
Min
Max
Unit
Input Voltage
Continuous
V
IN
-0.3 80 Vdc
Transient (100ms)
V
IN, trans
-0.3 100 Vdc
Operating Ambient Temperature
All
T
A
-40 85 °C
(see
Thermal
Considerations
section)
Storage Temperature
All
T
stg
-55 125 °C
I/O Isolation Voltage (100% factory Hi-Pot tested)
All
1500 Vdc
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.
Parameter
Device
Symbol
Min
Typ
Max
Unit
Operating Input Voltage
V
IN
36 48
75 Vdc
Maximum Input Current
I
IN,max
6
Adc
(V
IN
=0V to 60V, I
O
=I
O, max
)
Inrush Transient
All
I
2
t
1
A
2
s
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 12μH source impedance; V
IN
=0V to
75V, I
O
= I
Omax
; see Figure 31)
All
7
mAp-p
Input Ripple Rejection (120Hz)
All
50
dB
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to an
integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included,
however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies
require a fast-acting fuse with a maximum rating of 15A (see Safety Considerations section). Based on the
information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a
lower rating can be used. Refer to the fuse manufacturer’s data sheet for further information.