GE

Data Sheet

40A Analog MegaDLynx

TM

: Non-Isolated DC-DC Power Modules

4.5Vdc –14.4Vdc input; 0.6Vdc to 2.0Vdc output; 40A Output Current

April 24, 2013

©2012 General Electric Company. All rights reserved.

Page 14

Air

flow

x

Power Module

Wind Tunnel

PWBs

12.7_

(0.50)

76.2_

(3.0)

Probe Location

for measuring

airflow and

ambient

temperature

25.4_

(1.0)

Figure 29. Thermal Test Setup.

The thermal reference points, T

ref

used in the specifications

are also shown in Figure 30. For reliable operation the
temperatures at these points should not exceed 130°C. The
output power of the module should not exceed the rated
power of the module (Vo,set x Io,max).

Please refer to the Application Note “Thermal
Characterization Process For Open-Frame Board-Mounted
Power Modules” for a detailed discussion of thermal
aspects including maximum device temperatures.

Figure 30. Preferred airflow direction and location of hot-
spot of the module (Tref).