40a analog megadlynx, Non-isolated dc-dc power modules, Module – GE Industrial Solutions 40A Analog MegaDLynx User Manual

Page 15: Data sheet, Example application circuit

Advertising
background image

GE

Data Sheet

40A Analog MegaDLynx

TM

: Non-Isolated DC-DC Power Modules

4.5Vdc –14.4Vdc input; 0.6Vdc to 2.0Vdc output; 40A Output Current

April 24, 2013

©2012 General Electric Company. All rights reserved.

Page 15

Example Application Circuit

Requirements:
Vin:

12V

Vout:

1.8V

Iout:

30A max., worst case load transient is from 20A to 30A

Vout:

1.5% of Vout (27mV) for worst case load transient

Vin, ripple 1.5% of Vin (180mV, p-p)

CI1

Decoupling cap - 1x0.01

F/16V ceramic capacitor (e.g. Murata LLL185R71E103MA01)

CI2

3x22

F/16V ceramic capacitor (e.g. Murata GRM32ER61C226KE20)

CI3

470

F/16V bulk electrolytic

CO1

Decoupling cap - 1x0.01

F/16V ceramic capacitor (e.g. Murata LLL185R71E103MA01)

CO2

4 x 47µF/6.3V ceramic capacitor (e.g. Murata GRM31CR60J476ME19)

CO3

6 X330µF/6.3V Polymer (e.g. Sanyo Poscap)

CTune

5600pF ceramic capacitor (can be 1206, 0805 or 0603 size)

RTune

220 ohms SMT resistor (can be 1206, 0805 or 0603 size)

RTrim

10k

SMT resistor (can be 1206, 0805 or 0603 size, recommended tolerance of 0.1%)


VS-

GND

Vin+

CI3

CO3

VOUT

VS+

GND

TRIM

CTUNE

RTUNE

RTrim

VIN

CO1

CI1

Vout+

ON/OFF

SEQ

MODULE

PGOOD

SIG_GND

SYNC

CI2

CO2

SHARE

Advertising