2

Lineage Power

Data Sheet

March 27, 2008

18 Vdc to 36 Vdc or 36 Vdc to 75 Vdc Inputs, 10 W and 15 W

LC/LW010- and LC/LW015-Series Power Modules:

Absolute Maximum Ratings

Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are abso-
lute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess
of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended
periods can adversely affect device reliability.

* Maximum case temperature varies based on power dissipation. See derating curves, Figures 43—45, for details.

Electrical Specifications

Fusing Considerations

CAUTION: This power module is not internally fused. An input line fuse must always be used.

This encapsulated power module can be used in a wide variety of applications, ranging from simple stand-alone
operation to an integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal fus-
ing is not included; however, to achieve maximum safety and system protection, always use an input line fuse. The
safety agencies require a normal-blow, dc fuse with a maximum rating of 5 A (see Safety Considerations section).
Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same
type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data for further information.

Parameter

Device

Symbol

Min

Typ

Max

Unit

Input Voltage:

Continuous

Transient (100 ms)

LC

LW
LW

V

I

V

I

V

I, trans

0
0
0



50
80

100

Vdc
Vdc

V

Operating Case Temperature

(See Derating Curves, Figures 43—45.)

All

T

C

–40

105*

°C

Storage Temperature

All

T

stg

–55

125

°C

I/O Isolation

All

1500

Vdc

Table 1. Input Specifications

Parameter

Device

Symbol

Min

Typ

Max

Unit

Operating Input Voltage

LC

LW

V

I

V

I

18
36

24
48

36
75

Vdc
Vdc

Maximum Input Current

(V

I

= 0 to V

I, max

; I

O

= I

O, max

; see Figures

1—4.)

LC

LW

I

I, max

I

I, max



1.6

800

A

mA

Inrush Transient

All

I

2

t

0.2

A

2

s

Input Reflected-ripple Current

(5 Hz to 20 MHz; 12 µH source imped-
ance; T

A

= 25 °C; see Figure 33.)

All

I

I

5

mAp-p

Input Ripple Rejection (100 Hz—120 Hz)

All

45

dB