Characteristic curves, Electrical specifications – GE Industrial Solutions LC-LW015-Series User Manual

Page 7

Advertising
background image

Data Sheet

March 27, 2008

Lineage Power

7

18 Vdc to 36 Vdc or 36 Vdc to 75 Vdc Inputs, 10 W and 15 W

LC/LW010- and LC/LW015-Series Power Modules:

Electrical Specifications

(continued)

Output Voltage Set-point Adjustment Range

(optional: single outputs only)

A, B, F

C
D



90
90
90



110

100
125

%V

O, nom

%V

O, nom

%V

O, nom

Output Overvoltage Clamp

(V

O

,

clamp

may be set higher on units with out-

put voltage set-point adjustment option.)

D

F

A
B
C

AJ

BK

CL

V

O, clamp

V

O, clamp

V

O, clamp

V

O, clamp

V

O, clamp

V

O1, clamp

V

O2, clamp

V

O1, clamp

V

O2, clamp

V

O1, clamp

V

O2, clamp

2.60

3.7
5.6

13.2
16.5

5.6

–5.6
13.2

–13.2

16.5

–16.5











4.0
5.7
7.0

16.0
21.0

7.0

–7.0
18.0

–18.0

21.0

–21.0

V
V
V
V
V
V
V
V
V
V
V

Undervoltage Lockout

LCxxx

LWxxx

V

uvlo

V

uvlo

11

20

14
27


V
V

Table 5. Feature Specifications (continued)

Parameter

Device Code

or Suffix

Symbol

Min

Typ

Max

Unit

Characteristic Curves

8-1785(C)

Figure 1. LC010 Input Current vs. Input Voltage at

I

O

= I

O

,

max

and T

C

= 25 °C

8-1786(C)

Figure 2. LC015 Input Current vs. Input Voltage at

I

O

= I

O

,

max

and T

C

= 25 °C

5

10

15

25

20

30

0.0

0.6

INPUT VOLTAGE, V

I

(V)

0.4

0.3

0.5

35

0.8

40

0

0.7

0.2

0.1

0.9

INPUT CURRENT

,

I

I

(A)

0.4

0.0

0.8

1.2

1.4

0.2

0.6

1.0

5

10

15

35

20

40

0

30

25

INPUT VOLTAGE, V

I

(V)

INPUT CURRENT

,

I

I

(A)

Advertising