General specifications, Feature specifications – GE Industrial Solutions Naos Raptor 6A User Manual

Page 4

Advertising
background image

Data Sheet
December 6, 2010

Naos Raptor 6A: Non-isolated DC-DC Power Modules

4.5 – 14Vdc input; 0.59Vdc to 6Vdc Output; 6A output current

LINEAGE

POWER

4

General Specifications

Parameter

Min

Typ

Max

Unit

Calculated MTBF (V

IN

=12V, V

O

=5Vdc, I

O

=0.8I

O, max

, T

A

=40°C) Per

Telcordia Method

8,727,077 Hours

Weight

2.9 (0.10)

g (oz.)

Feature Specifications

Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions. See Feature Descriptions for additional information.

Parameter

Device

Symbol

Min

Typ

Max

Unit

On/Off Signal interface

(V

IN

=V

IN, min

to V

IN, max

; Open collector or equivalent

signal referenced to GND)

Logic High (On/Off pin open - Module ON)

Input High Current

All

I

IH

― 0.5 mA

Input High Voltage

All

V

IH

1.0 ― 12 V

Logic Low (Module Off)

Input Low Current

All

I

IL

― 200

μA

Input Low Voltage

All

V

IL

-0.3 ― 0.4 V

Turn-On Delay and Rise Times

(I

O

=I

O, max ,

V

IN

= V

IN, nom,

V

o

to within ±1% of steady state)

Case 1: On/Off input is enabled and then
input power is applied (delay from instant at which
V

IN

=V

IN, min

until Vo=10% of Vo,set)

All Tdelay

2

3 msec

Case 2: Input power is applied for at least one second
and then On/Off input is set enabled (delay from
instant at which On/Off is enabled until Vo=10% of Vo,
set)

All Tdelay

2

3 msec

Output voltage Rise time (time for Vo to rise from 10%
of V

o,set

to 90% of Vo, set)

All Trise

3 5

msec

Output voltage overshoot

0.5

% V

O, set

I

O

= I

O, max

; V

IN

= V

IN, min

to V

IN, max

, T

A

= 25

o

C

Overtemperature Protection

All

120 ºC

Input Undervoltage Lockout

Turn-on Threshold

All

4.2 Vdc

Turn-off Threshold

All

4.1 Vdc









Advertising