Data Sheet

SHHD001A3B Hammerhead Series; DC-DC Converter Power Modules

18-75Vdc Input; 12Vdc, 1.3A, 15W Output

October 30, 2013

©2012 General Electric Company. All rights reserved.

Page 3

Electrical Specifications

(continued)

Parameter

Device

Symbol

Min

Typ

Max

Unit

Output Voltage Set-point

12.0 V

O

V

O, set

11.82

12.00

12.18

V

dc

(V

IN

=24 to 48V

dc

, I

O

=I

O, max

, T

A

=25°C)

Output Voltage

All

V

O

-3.0

+3.0

% V

O, set

(Over all operating input voltage, resistive load, and temperature
conditions until end of life)

Adjustment Range

All

V

O, adj

-10

+10

% V

O, set

Selected by external resistor

Output Regulation

Line (V

IN

=V

IN, min

to V

IN, max

)

All

0.05

0.2

% V

O, set

Load (I

O

=I

O, min

to I

O, max

)

All

0.05

0.2

% V

O, set

Temperature (T

ref

=T

A, min

to T

A, max

)

All

1.0

% V

O, set

Output Ripple and Noise on nominal output

Measured with 10uF Tantalum||1uF ceramic

(V

IN

=24 to 48V

dc

, I

O

=80%I

O, max

,

T

A

=25°C)

RMS (5Hz to 20MHz bandwidth)

All

50

mV

rms

Peak-to-Peak (5Hz to 20MHz bandwidth)

150

mV

pk-pk

External Capacitance

All

C

O, max

0

470

μF

Output Current

All

I

o

0

1.3

A

dc

Output Current Limit Inception (Hiccup Mode)

All

I

O, lim

1.4

1.8

A

dc

Output Short-Circuit Current

All

I

O, s/c

0.8

A

rms

V

O

≤ 250 mV @ 25°C

Efficiency

V

IN

=24-48V

dc

, T

A

=25°C, I

O

=I

O, max

All

η

86.0

87.5

%

Switching Frequency (Fixed)

All

f

sw

350

kHz

V

IN

=24 to 48V

dc

and I

O

= I

O, max

Dynamic Load Response

(

I

O

/

t=0.1A/

s, V

IN

=24 to 48V

dc

, T

A

=25°C)

Load Change from I

O

= 50% to 75% or 25% to 50% of I

O,max

:

Peak Deviation

All

V

pk

3.0

% V

O, set

Settling Time (Vo<10% peak deviation)

All

t

s

800

s

Isolation Specifications

Parameter

Symbol

Min

Typ

Max

Unit

Isolation Capacitance

C

iso

1000

pF

Isolation Resistance

R

iso

10

I/O Isolation Voltage

All

2250

Vdc

General Specifications

Parameter

Min

Typ

Max

Unit

Calculated Reliability based upon Telcordia SR-332 Issue 2: Method I Case 3
(V

IN

=48V

dc

, I

O

=80%xI

O, max

, T

A

=40°C, airflow = 200 LFM, 90% confidence)

FIT

127.1

10

9

/Hours

MTBF

7,866,035

Hours

Weight

8.0 (0.28)

g (oz.)