Data sheet, Feature description – GE Industrial Solutions SHHD001A3B Hammerhead Series User Manual

Page 7

Advertising
background image

GE

Data Sheet

SHHD001A3B Hammerhead Series; DC-DC Converter Power Modules

18-75Vdc Input; 12Vdc, 1.3A, 15W Output

October 30, 2013

©2012 General Electric Company. All rights reserved.

Page 7

Feature Description

Remote On/Off

Two remote on/off options are available. Positive logic turns
the module on during a logic high voltage on the on/off pin,
and off during a logic low. Negative logic remote on/off, device
code suffix “1”, turns the module off during a logic high and on
during a logic low.

ON/OFF

Vin+

Vin-

I

on/off

V

on/off

Vout+

TRIM

Vout-

Figure 10. Circuit configuration for using Remote On/Off
Implementation.
To turn the power module on and off, the user must supply a
switch (open collector or equivalent) to control the voltage
(V

on/off

) between the ON/OFF terminal and the V

IN

(-) terminal.

Logic low is 0V ≤ V

on/off

≤ 0.8V. The maximum I

on/off

during a

logic low is 1mA, the switch should be maintain a logic low
level whilst sinking this current.
During a logic high, the typical V

on/off

generated by the module

is 2.4V, and the maximum allowable leakage current at V

on/off

=

2.4V is 25μA.
If not using the remote on/off feature:
For positive logic, leave the ON/OFF pin open.
For negative logic, short the ON/OFF pin to V

IN

(-).

Overcurrent Protection

To provide protection in a fault (output overload) condition, the
unit is equipped with internal current-limiting circuitry and can
endure current limiting continuously. At the point of
current-limit inception, the unit enters hiccup mode. The unit
operates normally once the output current is brought back into
its specified range. The average output current during hiccup
is 10% I

O, max

.

Overtemperature Protection

To provide protection under certain fault conditions, the unit is
equipped with a thermal shutdown circuit. The unit will
shutdown if the thermal reference point Tref (Figure 16),
exceeds 125

o

C (typical), but the thermal shutdown is not

intended as a guarantee that the unit will survive
temperatures beyond its rating. The module will automatically
restart upon cool-down to a safe temperature.

Input Undervoltage Lockout

At input voltages below the input undervoltage lockout limit,
the module operation is disabled. The module will only begin
to operate once the input voltage is raised above the
undervoltage lockout turn-on threshold, V

UV/ON

. Once

operating, the module will continue to operate until the input

voltage is taken below the undervoltage turn-off threshold,
V

UV/OFF

.

Over Voltage Protection

The output overvoltage protection shall consist of circuitry that
independently monitors the output voltage, and shuts the
module down if the output voltage exceeds specified limits.
The module shall contain hiccup restart capability.

Output Voltage Programming

Trimming allows the user to increase or decrease the output
voltage set point of the module. This is accomplished by
connecting an external resistor between the TRIM pin and
either the Vout+ pin or the Vout- pin.

Trim Down – Decrease Output Voltage

By connecting an external resistor between the TRIM pin and
Vout+ pin (Radj-down), the output voltage set point decreases
(see figure 11). The following equation determines the external
resistor value to obtain an output voltage change from V

o,nom

to the desired V

o,adj

:

H

V

V

G

V

R

adj

o

nom

o

adj

o

down

adj

)

(

)

5

.

2

(

,

,

,

Note: Values for G and H are defined in Table 1.



Table 1. Trim Constants SHHD series

Vout+

TRIM

Vout-

R

adj-down

R

LOAD

Vin+

ON/OFF

Vin-

Figure 11. Circuit Configuration to Decrease Output Voltage.

Trim Up – Increase Output Voltage

By connecting an external resistor between the TRIM pin and
Vout- pin (Radj-up), the output voltage set point increases (see
figure 12). The following equation determines the external
resistor value to obtain an output voltage change from V

o,nom

to the desired V

o,adj

:

H

K

V

G

R

adj

o

up

adj

)

5

.

2

(

5

.

2

,

Note: Values for G, H and K are defined in Table 1.

The combination of the output voltage adjustment and the
output voltage initial tolerance must not exceed the allowable
trim range of 90% to 110% of the nominal output voltage as
measured between the Vout+ and Vout- pins.

Module

G

H

K

SHHD001A3B

10000

5110

9.5

Advertising