Data sheet – GE Industrial Solutions SHHD001A3B Hammerhead Series User Manual

Page 8

Advertising
background image

GE

Data Sheet

SHHD001A3B Hammerhead Series; DC-DC Converter Power Modules

18-75Vdc Input; 12Vdc, 1.3A, 15W Output

October 30, 2013

©2012 General Electric Company. All rights reserved.

Page 8

Feature Descriptions

(continued)

Vout+

TRIM

Vout-

R

adj-up

R

LOAD

Vin+

ON/OFF

Vin-

Figure 12. Circuit Configuration to Increase Output Voltage.

The SHHD power modules have a fixed current-limit set point.
Therefore, as the output voltage is adjusted down, the
available output power is reduced.
Trim Examples
For SHHD005A0, nominal 5.0V module. To trim module down
to 11.9V:

5110

)

9

.

11

0

.

12

(

10000

)

5

.

2

9

.

11

(

down

adj

R

890

,

934

down

adj

R

Thermal Considerations

The power modules operate in a variety of thermal
environments; however, sufficient cooling should be provided
to help ensure reliable operation.

Considerations include ambient temperature, airflow, module
power dissipation, and the need for increased reliability. A
reduction in the operating temperature of the module will
result in an increase in reliability.

The thermal data presented here is based on physical
measurements taken in a wind tunnel, using automated
thermo-couple instrumentation to monitor key component
temperatures: FETs, diodes, control ICs, magnetic cores,
ceramic capacitors, opto-isolators, and module pwb
conductors, while controlling the ambient airflow rate and
temperature. For a given airflow and ambient temperature, the
module output power is increased, until one (or more) of the
components reaches its maximum derated operating
temperature, as defined in IPC-9592A. This procedure is then
repeated for a different airflow or ambient temperature until a
family of module output derating curves is obtained.

Figure 13. Thermal Test Setup .

O

U

TP

U

T

C

U

RR

EN

T,

I

O

(A)

LOCAL AMBIENT TEMPERATURE, T

A

(

C)

Figure 14. Output Current Derating for the Open Frame
SHHD001A3B in the Transverse Orientation; Airflow
Direction from Vin(-) to Vin(+); Vin = 24V.

O

U

TP

U

T

C

U

RR

EN

T,

I

O

(A)

LOCAL AMBIENT TEMPERATURE, T

A

(

C)

Figure 15. Output Current Derating for the Open Frame
SHHD001A3B in the Transverse Orientation; Airflow
Direction from Vin(-) to Vin(+); Vin = 48V.