Digital Feature Descriptions

PMBus Interface Capability

The 6A Digital PicoDLynx

TM

power modules have a PMBus

interface that supports both communication and control. The
PMBus Power Management Protocol Specification can be

obtained from

www.pmbus.org.

The modules support a

subset of version 1.1 of the specification (see Table 6 for a list
of the specific commands supported). Most module

parameters can be programmed using PMBus and stored as
defaults for later use.
All communication over the module PMBus interface must
support the Packet Error Checking (PEC) scheme. The PMBus
master must generate the correct PEC byte for all
transactions, and check the PEC byte returned by the
module.
The module also supports the SMBALERT# response protocol
whereby the module can alert the bus master if it wants to
talk. For more information on the SMBus alert response
protocol, see the System Management Bus (SMBus)
specification.
The module has non-volatile memory that is used to store

configuration settings. Not all settings programmed into the
device are automatically saved into this non-volatile memory,
only those specifically identified as capable of being stored

can be saved (see Table 6 for which command parameters
can be saved to non-volatile storage).

PMBus Data Format

For commands that set thresholds, voltages or report such
quantities, the module supports the “Linear” data format
among the three data formats supported by PMBus. The
Linear Data Format is a two byte value with an 11-bit, two’s
complement mantissa and a 5-bit, two’s complement
exponent. The format of the two data bytes is shown below:

Data Byte High

7 6 5 4 3

2 1 0 7 6 5 4 3 2 1 0

Data Byte Low

Exponent

MSB

Mantissa

MSB

The value is of the number is then given by

Value = Mantissa x 2

Exponent

PMBus Addressing

The power module can be addressed through the PMBus
using a device address. The module has 64 possible
addresses (0 to 63 in decimal) which can be set using
resistors connected from the ADDR0 and ADDR1 pins to
SIG_GND. Note that some of these addresses (0, 1, 2, 3, 4, 5,
6, 7, 8, 12, 40 in decimal) are reserved according to the

SMBus specifications and may not be useable. The address is
set in the form of two octal (0 to 7) digits, with each pin
setting one digit. The ADDR1 pin sets the high order digit and

ADDR0 sets the low order digit. The resistor values suggested
for each digit are shown in Table 4 (1% tolerance resistors

are recommended). Note that if either address resistor value

is outside the range specified in Table 4, the module will
respond to address 127.

Table 4

Digit

Resistor Value (KΩ)

0 10
1 15.4
2 23.7
3 36.5
4 54.9
5 84.5
6 130
7 200


The user must know which I

2

C addresses are reserved in a

system for special functions and set the address of the
module to avoid interfering with other system operations.

Both 100kHz and 400kHz bus speeds are supported by the
module. Connection for the PMBus interface should follow
the High Power DC specifications given in section 3.1.3 in the

SMBus specification V2.0 for the 400kHz bus speed or the
Low Power DC specifications in section 3.1.2. The complete
SMBus specification is available from the SMBus web site,

smbus.org

.

ADDR0

SIG_GND

R

ADDR0

R

ADDR1

ADDR1

Figure 48. Circuit showing connection of resistors used to
set the PMBus address of the module.

PMBus Enabled On/Off

The module can also be turned on and off via the PMBus
interface. The OPERATION command is used to actually turn

the module on and off via the PMBus, while the
ON_OFF_CONFIG command configures the combination of
analog ON/OFF pin input and PMBus commands needed to

turn the module on and off. Bit [7] in the OPERATION
command data byte enables the module, with the following

functions:

0

:

Output is disabled

1 : Output

is

enabled

This module uses the lower five bits of the ON_OFF_CONFIG
data byte to set various ON/OFF options as follows:

Bit Position

4

3

2

1

0

Access

r/w r/w r/w r/w r

Function PU

CMD

CPR

POL

CPA

Default Value

1

0

1

1

1