6a digital picodlynx, Non-isolated dc-dc power modules, Data sheet – GE Industrial Solutions 6A Digital PicoDLynx User Manual

Page 29

Advertising
background image

GE

Data Sheet

6A Digital PicoDLynx

TM

: Non-Isolated DC-DC Power Modules

3Vdc –14.4Vdc input; 0.45Vdc to 5.5Vdc output; 6A Output Current

April 29, 2013

©2013 General Electric Company. All rights reserved.

Page 29

Table 6 (continued)

Hex

Code

Command

Brief Description

Non-Volatile

Memory Storage

5F POWER_GOOD_OFF

Sets the output voltage level at which the PGOOD pin is de-asserted low

Format

Linear, two’s complement binary

Bit Position

7 6 5 4 3 2 1 0

Access

r r/w r/w

r/w

r/w

r/w

r/w r/w

Function

High Byte

Default Value

0 0 0 0 0 1 0 0

Bit Position

7 6 5 4 3 2 1 0

Access

r/w r/w r/w

r/w

r/w

r/w

r/w r/w

Function

Low Byte

Default Value

0 1 0 1 0 0 1 0

YES

61 TON_RISE

Sets the rise time of the output voltage during startup

Format

Linear, two’s complement binary

Bit Position

7 6 5 4 3 2 1 0

Access

r r r

r

r

r

r r/w

Function

Exponent Mantissa

Default Value

1 1 1 0 0 0 0 0

Bit Position

7 6 5 4 3 2 1 0

Access

r/w r/w r/w

r/w

r/w

r/w

r/w r/w

Function

Mantissa

Default Value

0 0 1 0 1 0 1 0

YES

78 STATUS_BYTE

Returns one byte of information with a summary of the most critical module

faults

Format

Unsigned Binary

Bit Position

7 6 5 4 3 2 1 0

Access

r r r

r

r

r

r r

Flag

X OFF

VOUT

_OV

IOUT_

OC

VIN_U

V

TEMP CML OTHE

R

Default Value

0 0 0 0 0 0 0 0

79 STATUS_WORD

Returns two bytes of information with a summary of the module’s fault/warning
conditions

Format

Unsigned Binary

Bit Position

7 6 5 4 3 2 1 0

Access

r r r

r

r

r

r r

Flag

VOUT

IOUT_

OC

X X

PGOO

D

X X X

Default Value

0 0 0 0 0 0 0 0

Bit Position

7 6 5 4 3 2 1 0

Access

r r r

r

r

r

r r

Flag

X OFF

VOUT

_OV

IOUT_

OC

VIN_U

V

TEMP CML

OTHE

R

Default Value

0 0 0 0 0 0 0 0

7A STATUS_VOUT

Returns one byte of information with the status of the module’s output voltage

related faults

Format

Unsigned Binary

Bit Position

7

6 5

4

3 2 1 0

Access

r r

r

r

r

r

r r

Flag

VOUT_OV X X VOUT_UV X X X X

Default Value

0

0 0

0

0 0 0 0

7B STATUS_IOUT

Returns one byte of information with the status of the module’s output current

related faults

Format

Unsigned Binary

Bit Position

7 6 5 4

3

2

1

0

Access

r r r

r

r

r

r r

Flag

IOUT_OC X

IOUT_OC_WARN X X X

X X

Default Value

0 0 0 0

0

0

0

0

Advertising