6a digital picodlynx, Non-isolated dc-dc power modules, Data sheet – GE Industrial Solutions 6A Digital PicoDLynx User Manual

Page 30

Advertising
background image

GE

Data Sheet

6A Digital PicoDLynx

TM

: Non-Isolated DC-DC Power Modules

3Vdc –14.4Vdc input; 0.45Vdc to 5.5Vdc output; 6A Output Current

April 29, 2013

©2013 General Electric Company. All rights reserved.

Page 30

Table 6 (continued)

Hex

Code

Command

Brief Description

Non-Volatile

Memory Storage

7D STATUS_TEMPERATURE

Returns one byte of information with the status of the module’s temperature
related faults

Format

Unsigned Binary

Bit Position

7

6

5 4 3 2 1 0

Access

r r

r

r

r

r

r r

Flag

OT_FAULT OT_WARN X X X X X X

Default Value

0

0

0 0 0 0 0 0

7E STATUS_CML

Returns one byte of information with the status of the module’s communication
related faults

Format

Unsigned Binary

Bit Position

7

6 5 4 3 2 1 0

Access

r r

r

r

r

r

r r

Flag

Invalid

Command

Invalid

Data

PEC

Fail

X X X

Other

Comm

Fault

X

Default Value

0

0 0 0 0 0 0 0

88 READ_VIN

Returns the value of the input voltage applied to the module

Format

Linear, two’s complement binary

Bit Position

7 6 5 4 3 2 1 0

Access

r r r

r

r

r

r r

Function

Exponent Mantissa

Default Value

1 1 0 1 1 0 0 0

Bit Position

7 6 5 4 3 2 1 0

Access

r r r

r

r

r

r r

Function

Mantissa

Default Value

0 0 0 0 0 0 0 0

8B READ_VOUT

Returns the value of the output voltage of the module

Format

Linear, two’s complement binary

Bit Position

7 6 5 4 3 2 1 0

Access

r r r

r

r

r

r r

Function

Mantissa

Default Value

0 0 0 0 0 0 0 0

Bit Position

7 6 5 4 3 2 1 0

Access

r r r

r

r

r

r r

Function

Mantissa

Default Value

0 0 0 0 0 0 0 0

8C READ_IOUT

Returns the value of the output current of the module

Format

Linear, two’s complement binary

Bit Position

7 6 5 4 3 2 1 0

Access

r r r

r

r

r

r r

Function

Exponent Mantissa

Default Value

1 1 1 0 0 0 0 0

Bit Position

7 6 5 4 3 2 1 0

Access

r r r

r

r

r

r r

Function

Mantissa

Default Value

0 0 0 0 0 0 0 0

98 PMBUS_REVISION

Returns one byte indicating the module is compliant to PMBus Spec. 1.1 (read
only)

Format

Unsigned Binary

Bit Position

7 6 5 4 3 2 1 0

Access

r r r

r

r

r

r r

Default Value

0 0 0 1 0 0 0 1

YES

Advertising