Absolute maximum ratings, Electrical specifications – GE Industrial Solutions HW-HC004-005-006 Series User Manual

Page 2

Advertising
background image

Data Sheet

October 4, 2013

HW/HC004/005/006 Series DC-DC Power Module:

18-36Vdc & 36-75Vdc Input; 1.0V-5Vdc Output; 4A - 6A Output Current

LINEAGE

POWER

2

Absolute Maximum Ratings

Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for
extended periods can adversely affect the device reliability.

Parameter

Device

Symbol

Min

Max

Unit

Input Voltage

HC

V

IN

-0.3

50

Vdc

Continuous

HW

V

IN

-0.3

80

Vdc

Transient (100ms)

HW

V

IN, trans

-0.3

100

Vdc

Operating Ambient Temperature

All

T

A

-40

85

°C

(see Thermal Considerations section)

Storage Temperature

All

T

stg

-55

125

°C

I/O Isolation Voltage (100% factory tested)

All

2250

Vdc

Electrical Specifications

Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.

Parameter

Device

Symbol

Min

Typ

Max

Unit

Operating Input Voltage

HC

V

IN

18

24

36

Vdc

HW

V

IN

36

54

75

Vdc

Maximum Input Current

HC

I

IN,max

1.75

Adc

(V

IN

=0V to 75V, I

O

=I

O, max

)

HW

I

IN,max

0.85

Adc

Inrush Transient

All

I

2

t

1

A

2

s

Input Reflected Ripple Current, peak-to-peak

(5Hz to 20MHz, 12μH source impedance; V

IN

=0V to

75V, I

O

= I

Omax

; see Figure 9)

All

5

mAp-p

Input Ripple Rejection (120Hz)

All

50

dB

EMC, EN55022

See EMC Considerations section

CAUTION: This power module is not internally fused. An input line fuse must always be used.

This power module can be used in a wide variety of applications, ranging from simple standalone operation to being
part of complex power architecture. To preserve maximum flexibility, internal fusing is not included; however, to
achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a fast-
acting fuse with a maximum rating of 3A (see Safety Considerations section). Based on the information provided in
this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be
used. Refer to the fuse manufacturer’s data sheet for further information.