Data Sheet

October 4, 2013

HW/HC004/005/006 Series DC-DC Power Module:

18-36Vdc & 36-75Vdc Input; 1.0V-5Vdc Output; 4A - 6A Output Current

LINEAGE

POWER

5

Feature Specifications

Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions. See Feature Descriptions for additional information.

Parameter

Device

Symbol

Min

Typ

Max

Unit

Remote On/Off Signal Interface

(V

IN

=V

IN, min

to V

IN, max

; open collector or equivalent,

Signal referenced to V

IN-

terminal)

Negative Logic: device code suffix “1”

Logic Low = module On, Logic High = module Off

Positive Logic: No device code suffix required

Logic Low = module Off, Logic High = module On

Logic Low Specification

Remote On/Off Current – Logic Low

All

I

on/off

0.15

1.0

mA

On/Off Voltage:

Logic Low

All

V

on/off

0.0

1.2

V

Logic High – (Typ = Open Collector)

All

V

on/off

5.8

15

V

Logic High maximum allowable leakage current

All

I

on/off

10

μA

Turn-On Delay and Rise Times

(I

O

=I

O, max

)

T

delay

= Time until V

O

= 10% of V

O,set

from either

application of Vin with Remote On/Off set to On or
operation of Remote On/Off from Off to On with Vin
already applied for at least one second.

5V, 3.3V

T

delay

100

ms

T

rise

40

ms

2.5V, 2.0V,
1.8V, 1.5V,

1.2V, 1.0V

T

delay

12

ms

T

rise

= time for V

O

to rise from 10% of V

O,set

to 90%

of V

O,set

.

T

rise

3

ms

5V

V

O, limit

7.0

V

Output Overvoltage Protection

#

3.3V

4.6

V

2.5V

3.5

V

Values are the same for HW and HC codes

2.0V

3.2

V

1.8V

2.8

V

1.5V

2.5

V

1.2V

2.0

V

1.0V

1.8

V

Overtemperature Protection

All

T

ref

125

°C

(See Feature Descriptions)

Input Undervoltage Lockout

Turn-on Threshold

All HW

33

36

V

Turn-off Threshold

All HW

27

30

V

Turn-on Threshold

All HC

17

18

V

Turn-off Threshold

All HC

13.5

15

V

# More accurate Overvoltage protection can be accomplished externally by means of the remote On/Off pin.

Advertising