Kbvw006a0b series sixteenth-brick power modules, Data sheet, Feature specifications – GE Industrial Solutions KBVW006A0B Series User Manual

Page 4

Advertising
background image

GE

Data Sheet

KBVW006A0B Series Sixteenth-Brick Power Modules

36–75Vdc Input; 12.0Vdc Output; 6A Output Current

July 9, 2013

©2012 General Electric Company. All rights reserved.

Page 4

Feature Specifications

Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See

Feature Descriptions for additional information.

Parameter

Device

Symbol

Min

Typ

Max

Unit

Remote On/Off Signal Interface

(V

IN

=V

IN, min

to V

IN, max

; open collector or equivalent,

Signal referenced to V

IN-

terminal)

Negative Logic: device code suffix “1”

Logic Low = module On, Logic High = module Off

Positive Logic: No device code suffix required

Logic Low = module Off, Logic High = module On

Logic Low - Remote On/Off Current

All

I

on/off

0.15 mA

Logic Low - On/Off Voltage

All

V

on/off

-0.7

0.6 V

dc

Logic High Voltage – (Typ = Open Collector)

All

V

on/off

2.4

15 V

dc

Logic High maximum leakage current

All

I

on/off

25

μA

Turn-On Delay

1

and Rise Times

(I

O

=I

O, max ,

V

IN

=V

IN, nom,

T

A

= 25

o

C)

Case 1: Input power is applied for at least 1 second
and then the On/Off input is set from OFF to ON (T

delay

= from

instant at which On/Off signal is ON until V

O

= 10% of V

O, set

).

All T

delay

— 20

— msec

Case 2: On/Off input is set to Logic Low (Module
ON) and then input power is applied (T

delay

from

instant at which V

IN

= V

IN, min

until V

o

=10% of V

O,set

)

All T

delay

— — 150 msec

Output voltage Rise time (time for V

o

to rise from 10%

of V

o,set

to 90% of V

o, set

)

All T

rise

— 5 12 msec

Output voltage overshoot – Startup

All

— 3

%

V

O, set

I

O

= I

O, max

; V

IN

=V

IN, min

to V

IN, max

, T

A

= 25

o

C

Prebiased Output Load Performance:

All Monotonic

Output Start up characteristic

Back Bias current drawn from output (Module Enabled)

All

-50

mA

dc

Back Bias current drawn from output (Module Disabled)

All

-50

mA

dc

Remote Sense Range

All

V

SENSE

10 %

V

O, set

Output Voltage Adjustment Range

All

80

110

% V

O, set

Output Overvoltage Protection

All V

O, limit

13.8

16.5 V

dc

Overtemperature Protection – Hiccup Auto Restart

All

T

ref

135

O

C

Input Undervoltage Lockout

All

V

UVLO

Turn-on Threshold

32 34.5 V

dc

Turn-off Threshold

27.5 30

V

dc

Hysteresis

1 2

V

dc

1.

The module has an adaptable extended Turn-On Delay interval, T

delay

, of 25mS. The extended T

delay

will occur when the module restarts following either: 1)

the rapid cycling of Vin from normal levels to less than the Input Undervoltage Lockout (which causes module shutdown), and then back to normal; or 2)
toggling the on/off signal from on to off and back to on without removing the input voltage. The normal Turn-On Delay interval, T

delay

, will occur whenever a

module restarts with input voltage removed from the module for the preceding 1 second.

2.

The module requires a minimum of 220

μF external output capacitor to prevent shutdown during no load to full load transients and to avoid exceeding the

OVP maximum limits during startup into open loop fault conditions.

Advertising