Data logger, Ph oxy cond, The data logger – Xylem HandyLab 780 User Manual

Page 68

Advertising
background image

68

pH

Oxy Cond

The Data Logger

The meter provides a data logger. Prior to use, it must be confi gured and
then activated. You can choose from the following logger types:
• Shot (manual logging by pressing the Save value softkey)
• Interval (time-controlled logging at a fi xed interval)
• Difference (signal-controlled logging of measured variable and tempera-

ture)

• Intv+Diff (combined time- and signal-controlled logging)
• Limit value (combined time- and threshold-controlled logging)

The data logger records up to 10 000 entries, which can be assigned to
different points of measurement (TAGs) and notes. The following data will be
recorded: meas. point, note, sensor ID, serial number of sensor (Memosens),
primary value, temperature, time stamp, device status.
The HandyLab Pilot software allows convenient management of the data
logger.
It is always the currently selected process variable which is recorded.

Display: Icons related to the data logger

Data logger full

Data logger activated

Number of measured values stored

Circular

recording

Save value manually (shot)

If logger
full

Menu

Hold value

Temperature

Process
variable

Data Logger

Advertising