The complete lack of moving parts of the EX100/200-Series insertion

flow sensor is the source of its reliability. Brass and stainless steel

models withstand a variety of temperature, pressure, and chemical

conditions. The EX-Series has no rotor to stop turning in dirty water

and there are no bearings to wear out.

A rapidly reversing magnetic field is produced in the lower housing.

As the fluid moves through this field, a voltage is generated that is

measured and translated into a frequency signal proportional to flow

rate. This square wave signal can be sent directly to a PLC or other

control or can be converted using any of the Seametrics family of

indicators and converters.

A modular system of electronics can be attached directly to the flow

sensor or remotely mounted. The Seametrics FT420 provides full

indication of rate and total, plus 4-20 mA output. The AO55 provides

blind 4-20 mA output, and the DL76 is a battery-powered data

logger.

The adapter of the EX mates with a standard female NPT fitting,

and can be directly threaded into ordinary saddles or threaded weld

fittings. The EX115 and 215 include an isolation valve, allowing hot-tap

installation, or installation and removal under pressure; a bronze ball

valve is standard, with a 316 stainless steel valve option if needed.

Reverse flow output and immersibility are optional.

GENERAL INFORMATION, FEATURES and SPECIFICATIONS

Page 1

FEATURES

Valve assembly for

hot tap installation

EX115/215

Brass or 316 Stainless Shaft

Lower Housing

Adapter mates with

1 1/2” FNPT threaded fitting

Compression Nut

Sensor Housing

Electrodes and Cap

Housing Screw (connect ground to one)

Cover or Electronics Module

Cable Strain Relief

EX101/201

3” to 48” (up to 72” optional)

316 SS or Brass

Hastelloy

PVDF

Cast powder-coated aluminum

Bronze (stainless optional) with bronze ball valve

EPDM

12-25 Vdc, 250 mA

12-25 Vdc, 40 mA average with 250 mA peaks

0.28 to 20 ft/sec (0.08 - 6.09 m/sec)
EX101/201

EX115/215

1-1/2” FNPT

2” FNPT

0˚ to 160˚ F (-17˚ to 72˚ C)

32˚ to 200˚ F (0˚ to 93˚ C)

200 psi (13.8 bar)

20 microSiemens/cm

+/- 1% of full scale

Square wave pulse, opto isolated, 550 Hz @ 20 ft/sec

6 mA max, 30 Vdc forward flow standard; reverse flow optional

Software, defaults to zero flow

Pipe Sizes

Materials Shaft/Fitting

Electrodes

Electrode Cap

Housing

Valve Assembly

(115/215 Only)

O-Ring

(115/215 Only)

Power

Full Power

Low Power

Flow Range

Fitting Size Required

Temperature Ambient

Fluid

Pressure

Minimum Conductivity

Calibration Accuracy

Output

Empty Pipe Detection

SPECIFICATIONS*

*Specifications subject to change • Please consult our website for current data (www.seametrics.com).