John Wood Takagi - 320H-520H User Manual

Page 10

Advertising
background image

10

PVC Venting Illustrations
Horizontal Installation Diagram (With elbow terminations)

Wall

Connection between exhaust
vent collar and PVC piping. See
the next page for instructions.

Vertical Installation Diagram

Roof

Fire stop

Connection between exhaust
vent collar and PVC piping. See
the next page for instructions.

Roof Flashing

Horizontal Installation Diagram (With 76mm (3 in.) PVC
Concentric Termination)

Keep a 25mm (1 in.) clearance between
wall and the intake section of the concentric
termination. See the diagram below.

Wall

Connection between
exhaust vent collar and PVC
piping. See the next page for
instructions.

25mm (1 in.)

min. clearance

Concentric

Termination

Insert the bird

screen included

with the termination.

How to install PVC venting with the 520H (For Exhaust)
1. Connect the TH-PA01 PVC adaptor* directly on the

exhaust vent collar of the water heater.

2. Connect a 102mm (4 in.) PVC coupler (or 4x3" PVC

reducer) to the TH-PA01 PVC adaptor.

3. From the coupler (or reducer), continue on the rest of the

vent run with 102mm (4 in.) PVC pipe (or 76mm (3 in.)
PVC pipe.)

(For Intake: 102mm (4 in.) only)

Connect a 102mm (4 in.) PVC Straight pipe directly on
the intake vent collar of the water heater.

102mm (4 in.)
PVC straight pipe

102mm (4 in.)

PVC straight pipe

102mm (4 in.)
PVC coupler

TH-PA01 PVC
adaptor*

Exhaust vent collar of
the 520H (Female)

Intake vent collar

* TH-PA01 PVC adaptor
is included with the 520H.