Remote controller connection – John Wood Takagi - 320H-520H User Manual

Page 18

Advertising
background image

18

Remote Controller Connection

Disconnect power supply from the water heater.
Take off the water heater’s front cover.
Locate the remote controller terminal, pictured below
(located around the upper right-hand side of the com-
puter board).
Open the plastic cover of the remote controller acces-
sory, and then attach the two fork terminals to connec-
tor base of the backside the controller with two screws.
Make sure the terminals are firmly fixed.
Pull the remote’s wires through the rubber grommet at
the bottom of the water heater’s casing.

1.
2.
3.

4.

5.

Properly attach the remote’s wires to the remote con-
troller terminal on the computer board. (No polarity)
*Do NOT jump or short-circuit the wires or computer will
be damaged.
Replace Front Cover securely.
Wires used for the remote controller connection must
be:

Minimum 18AWG wire (No polarity)
Maximum 400 feet long

*For detailed connection instructions to the remote control-
ler accessory, refer to the remote controller’s Installation
Manual.

6.

7.
8.


Remote controller terminal of the 520H

Front of remote

Back of remote

Connect other end

to these terminals

Connect to

these terminals