Error mode

When the integrated control detects a failure condition it
enters Error mode. In this mode the display alternates
between showing “Err” and an error code number, display-
ing each for one (1) second. The display characters for each

error and their definitions are shown in Figure 21. While in
Error mode the functions of the buttons are disabled. The
integrated control returns to Reading mode only if all error
conditions are cleared.

Reading mode

The integrated control defaults to Reading mode after a
reset. This mode is for information display only and no
adjustments can be made to parameter settings. The dis-
play characters for each parameter and their definitions are
shown in Figure 19. Use the “MODE” button to cycle

through the available parameters. Once a parameter is
selected, the (HOTTER) and (COOLER) buttons are
used to view the value of the selected parameter. If no but-
ton is pressed, the display will cycle through the parameter's
name, value and unit at one (1) second intervals.

Text

Description

Display Shows

Text

Description

Display Shows

loc

Reset the Hard Lockout
Flag

F-C

Set mode to °F or °C

rst

Reset the Soft Lockout
Timer

sp_

Set the Setpoint mode

Figure 20 Display readout definitions (Installer mode)

Display Shows

Display Shows

Description

Flame was sensed out of normal
sequence
Flame was sensed during pre-
purge

Description

AC line frequency error

AC line voltage error

Over Temperature error - ECO
limit exceeded

Flame Rod shorted to burner
ground

Line volage unstable

Soft Lockout - Max number of
retries exceeded
Soft Lockout - Max number of
recycles exceeded

Soft Lockout - Electronics failure

Atmospheric Damper End Switch
failed to open

Flame was sensed during post-
purge
Temp. sensor(2), interface or A/D
conversion failure
Temp. sensor(1), interface or A/D
conversion failure
Atmospheric Damper End Switch
failed to close

Figure 21 Display readout definitions (Error mode)

Installer mode

The integrated control must be in installer mode in order for
the parameters (see Figure 20) to be adjusted. This mode is
entered by pressing and holding all three buttons simulta-
neously for about three (3) seconds. Repeating this action,
or if no key is pressed for 60 seconds, will set the integrat-
ed control back to Reading mode. Use the “MODE”

button to cycle through the available parameters. Once a
parameter is selected, use the (HOTTER) and (COOL-
ER) buttons to adjust the value of the selected parameter. If
no key is pressed, the display cycles through parameter
name, value and unit at 1 second interval for 60 seconds
before returning to Reading mode.

Text

Description

Display Shows

Text

Description

Display Shows

sta

Current State

°F

Temp. Displayed is in
Degrees Fahrenheit

fla

Flame Current (Measured)

°C

Temp. Displayed is in
Degrees Celsius

sp

Current Setpoint

uA

Units Displayed are in
Micro Amps

s1t

Current Sensor 1
Temperature (Limit)

off

Input or Output is Off

s2t

Current Sensor 2
Temperature (2-wire)*

on

Input or Output is On

hr

Heat Request Status

Figure 19 Display readout definitions (Reading mode)

Advertising
This manual is related to the following products: