Danger – John Wood Commercial - AJWSC User Manual

Page 5

Advertising
background image

Safety Warning (Scalding)

Hot water produced by this appliance can cause severe
burns due to scalding. The hazard is increased for young
children, the aged or the disabled when water temperatures
exceed 52°C (125°F). Use tempering valves, also known as
mixing valves, in the hot water system to reduce the risk of
scalding at point-of-use such as lavatories, sinks and
bathing facilities. Such precautions must be followed when
this heater is operated in combination with dishwashing or
space heating applications.

Safety Warning (Carbon Monoxide)

As with all fuel burning equipment, this heater requires an
adequate supply of air for combustion and ventilation. An
insufficient air supply can result in poor combustion or the
re-circulation of the flue gases. Such a condition can cause
soot build-up and present a fire hazard. Flow reversal of flue
gases can cause an increase of carbon monoxide inside of
the dwelling that could result in serious bodily harm or death
from asphyxiation.

MAKE SURE THE FLOW OF COMBUSTION AND VENTI-
LATION AIR IS NOT RESTRICTED.

Relief Valve Requirements (T&P)

All water heaters must be fitted with a proper temperature
and pressure relief valve. These valves must be certified as
meeting the requirements of the “Standard For Relief
Valves For Hot Water Supply Systems, ANSI
Z21.22/CSA 4.4”
.

If this water heater has been exposed to flooding, freezing,
fire or any unusual condition, do not put it into operation until
it has been inspected and approved by a qualified service
technician.
THESE CONDITIONS CAN RESULT IN UNSEEN INTER-
NAL DAMAGE
and are not subject to warranty coverage.

CAUTION

Hydrogen gas can be produced in a hot water system
served by this heater that has not been used for a long
period of time (generally two (2) weeks or more).
Hydrogen gas is extremely flammable and can ignite
when exposed to a spark or flame.
To reduce the risk of
injury under these conditions, it is recommended that the
hot water faucet be opened for several minutes at the
kitchen sink before using any electrical appliance con-
nected to the hot water system. Use caution in opening
faucets. If hydrogen is present, there will probably be an
unusual sound such as air escaping through the pipe as
the water begins to flow. There should be no smoking or
open flame near the faucet at the time it is open.

DANGER

DANGER

Carbon Monoxide Warning

• Follow all vent system requirements by

the local authorities having jurisdiction
over your installation.

• Failure to do so can result in death, explo-

sion or carbon monoxide poisoning.

– 5 –

Advertising
This manual is related to the following products: