Command and response table for sis commands, A/v muting, A/v mute modes – Extron Electronics CTR 8 User Guide User Manual

Page 13: Command and response table for sis, Commands

Advertising
background image

CTR 8 • Remote Communication and Control

8

Command and Response Table for SIS Commands

Command

ASCII Command
(host to unit)

Response
(unit to host)

Additional
Description

Select input

X)

!

Chn

X)]

X)

= input 0-8

View last selected input

!

X)]

Query contact closure status S/s

X@X@X@X@X@X@X@X@]

Least significant input

on far left

Example response:

01000000

]

Contact input 2 is

selected

Unidirectional Serial Data Port

Configure port parameters

Example command:

E

2*

X2%

,n,8,1CP

}

E

2*19200,n,8,1CP

}

Cpn02•Ccp

X2%

,n,8,1

]

n = Parity = None
8 = Data bits
1 = Stop bit

View parameters

E

2CP

}

X2%

,n,8,1

]

A/V Mute Mode

Configure A/V mute mode

EX#

*

X$

MUTM

}

Mutm

X#

*

X$]

View A/V mute mode setting

E

MUTM

}

X#

*

X$]

Other

Information request

I/i

CTR

8

]

Request part number

N/n

60‑xxxx‑xx

]

View the part number

Query firmware version

Q/q

x.xx

]

Firmware build (2
decimal places)

Query full firmware version

*Q/*q

x.xx.xxxx

]

View the full firmware

Reset all device settings to
factory

E

zXXX

}

Zpx

]

A/V Muting

The CTR 8 allows A/V muting for a selected input. This feature allows users to press
the selected input button to mute and unmute the audio and video as needed during a
presentation.

Press the button once to select an input (Select state)

Press the same button again to activate A/V mute (De-select state)

Press the button once more to return to the Select state, which selects the input and
unmutes the audio and video.

NOTE:

The A/V mute feature is only triggered by contact closure. SIS input selection (for

example, entering 1! two times) will not trigger the de-select state.

A/V Mute Modes

There are three A/V mute modes, based on the device:

Mute mode 1: Mutes switcher input by selecting channel 0

Mute mode 2: Mutes video and audio individually

Mute mode 3: Mutes video and sync

Mute mode 0 is the normal (default) single state operation. A/V mute is not activated in this
mode.

NOTE:

See the next page for a partial list of Extron switchers that are compatible with

the different mute modes.

Advertising