Troubleshooting, Power connections – Extron Electronics IPL T PCS4i User Manual

Page 46

Advertising
background image

3.

At the

<to>

prompt, enter the IP address of the PCS4 unit. (The default IP address is

192.168.254.254

. If the address was changed in the setup or configuration process,

use the new address.) Telnet defaults to port 23.

Figure 33.

Connecting to the IP Address

4.

If passwords were set up for the connected system, you are prompted to log in as an
administrator or a user. Otherwise, the system responds with a carriage return and line
feed (

<cr/lf>

).

5.

Once you are connected, you can enter SIS commands as desired.

6.

When you are finished entering commands to the interface, press < Ctrl + ] >

at the

command prompt to exit Telnet.

Troubleshooting

Turn on the equipment in the following order:

1.

The PCS4 power control interface

2.

The power receptacles on the PCS4

3.

The connected output devices

If the output A/V device cannot be powered on, check the following:

Power Connections

1.

Make sure that the receptacle for each device is receiving power. The red Power LED of
the receptacle lights if the receptacle is powered on. If necessary, press the receptacle
button to apply power.

2.

Ensure that all devices are plugged in properly to the rear panel of the PCS4 and
switched on if applicable.

IPL T PCS4 • HTML Configuration and Control

40