SIS Programming

and Control

This section provides instructions on using the Extron Simple Instruction Set (SIS) commands,
which you can use to set up and control the IPL T PCS4 from a host computer or other
control system attached to the rear panel LAN port. The following topics are discussed:

Host-to-Interface Communication

Using the Command and Response Table

Symbol Definitions

Command and Response Table for SIS Commands

As shipped, the PCS4 works as a standalone interface, but cannot control any other devices
until it is configured. You can set up and control the PCS4 by using the front panel, the web
pages, or SIS commands. Both the web pages and the SIS methods are accessed via Ethernet
LAN connection. The LAN port defaults are:

IPL T PCS4 IP address:

192.168.254.254

Gateway IP address:

0.0.0.0

Subnet mask:

255.255.0.0

DHCP:

Off

Host-to-Interface Communication

SIS commands consist of one or more characters per field. No special characters are required
to begin or end a command sequence. When the PCS4 determines that a command is valid,
it executes the command and sends a response to the host device. All responses from the
interface to the host end with a carriage return and a line feed (CR/LF =

]

), which signals

the end of the response character string. (A string is one or more characters.)

Messages Initiated by the IPL T PCS4

When a local event such as a front panel selection or adjustment takes place, the PCS4
responds by sending a message to the host. No response is required from the host. The
following PCS4-initiated messages are sent (underlined):
©

Copyright

20nn,

Extron

Electronics,

IPL

T

PCS4

[or

-PCS4i

]

,

Vn.nn,

60-544-nn

]

Www,

DD

Mmm

2011

HH:MM:SS]

The PCS4 sends the boot and copyright messages when it first powers on and is connected
via Telnet or TCP/IP.

Vn.nn

is the firmware version number;

60-544-nn

is the product part

number. The current date and time are displayed. If you are using a Telnet connection, the
copyright message, date, and time are followed by a password prompt.

43

IPL T PCS4 • SIS Programming and Control