Local video output sync polarity – Extron Electronics MTPX Plus 6400 Series Setup Guide User Manual

Page 19

Advertising
background image

Command

ASCII Command
(Host to Unit)

Response
(Unit to Host)

Additional Description

Output skew adjustment

Set all output skew

adjustment values

EX@

*

X*

*

X*

*

X*

Oseq

}

Set a specific skew adjustment for the TP
output.

X*

values are listed in RGB order.

Oseq

X@

*

X*

red

*

X*

green

*

X*

blue

]

Example:

E

2*0*0*4Oseq

}

Oseq02*0*0*4

]

Set the skew settings for output 2 as follows:
Red = 0 ns
Green = 0 ns
Blue = 8 ns (4 x 2 ns)

Increment one output skew

adjustment value

EX@

*

X(

+Oseq

}

Increase the

X(

skew plane adjustment for

output

X@

by 1 step (2 ns).

Oseq

X@

*

X*

red

*

X*

green

*

X*

blue

]

Example:

E2*2*+Oseq

}

Oseq02*0*0*5

]

Increase the blue skew output for output 2 by
2 ns (from 8 ns to 10 ns).

Decrement one output skew

adjustment value

EX@

*

X(

-Oseq

}

Decrease the

X(

skew plane adjustment for

output

X@

by 1 step (2 ns).

Oseq

X@

*

X*

red

*

X*

green

*

X*

blue

]

Read output skew adjustment

values

EX@

Oseq

}

X*

red

*

X*

green

*

X*

blue

]

Output pre-peaking

Set output pre-peaking on

EX@

*1Opek

}

Opek

X@

*1

]

Pre-peak the TP output.

Set output pre-peaking off

EX@

*0Opek

}

Opek

X@

*0

]

Do not pre-peak the TP output.

Read output pre-peaking

setting

EX@

Opek

}

X1!]

NOTE:

X@

= Output number

01 – maximum number of outputs for your configuration

X*

= Skew adjustment range

00 – 31 (each step = 2 ns)

X(

= Video plane

0 = red

1 = green

2 = blue

X1!

= Pre-peaking status

0 = off, 1 = on

NOTE:

X@

= Output number

01 – maximum number of outputs for your configuration

X#

= Mute

0 = off (unmuted)

1 = on (muted)

X1@

= Local video output number

01 – 04

X1#

= Local output sync polarity

0 = H– /+ (default)

1 = H+ / V–

2 = H– / V+

3 = H+ / V+

4 = No sync stripping

X1$

= Audio or RS-232 mute

0 = no mute

2 = audio or RS-232 is muted

Command

ASCII Command
(Host to Unit)

Response
(Unit to Host)

Additional Description

Local video output sync polarity

Set local output polarity

EX1@

*

X1#

Opol

}

Opol

X1@

*

X1#]

Set the horizontal and vertical sync polarity
for local output

X1@

.

Example:

E

2*0Opol

}

Opol2*00

]

Set local output 2 to output negative
horizontal and vertical sync.

Read local output sync settings

EX1@

Opol

}

X1#]

Audio or RS-232 mute commands

Audio or RS-232 mute

X@

*1Z

Amt

X@

*1

]

Mute output

X@

(audio off).

Audio or RS-232 unmute

X@

*0Z

Amt

X@

*0

]

Unmute output

X@

(audio on).

Read audio or RS-232 mute

X@

Z

X#]

1 = mute on, 0 = mute off.

Global audio or RS-232 mute

1*Z

Amt1

]

Mute all audio outputs.

Global audio or RS-232 unmute

0*Z

Amt0

]

Unmute all audio outputs.

View output mutes

E

VM

}

X1$

1

X1$

2

...

X1$

n

]

Each

X1$

response is the mute status of an

output, starting from output 1.
n = the maximum number of outputs for your
configuration.

Example :
(MTPX Plus 6432)

E

VM

}

Outputs 2, 3, 5, 26, 27, and 29 are muted. All
other outputs are unmuted.

Mut02202000000000000000000002202000

]

NOTE: The "Mut" portion of the response appears only when the switcher is in Verbose mode 2 or 3 (see the

Verbose mode

SIS command on

page 33.

28

MTPX Plus 6400 • Remote Contr

ol and Optimizing the V

ideo

29

MTPX Plus 6400 • Remote Contr

ol and Optimizing the V

ideo

Advertising