Ethernet data port configuration and use

Set global IP port timeout period

24

Esc

1*

X6

9

TC

W1%2A

X6

9

TC

|

Pti 1*

X6

9

The global port timeout is the default

timeout period for all T

elnet sessions.

X6

9

=

IP connection timeout period in seconds.

Each step is specified in 10-second intervals

(1 - 65000, default = 30 = 300 seconds). If no

data is r

eceived during the specified period,

the Ethernet connection will be closed.

Responses are

r

eturned with leading zeros.

This variable is applicable only when the

MLC is connected via Ethernet, and you

must be logged in as an administrator to

change this setting.

V

iew global IP port timeout period

Esc

1TC

W1TC

|

X6

9

Set curr

ent port’s timeout period

24

Esc

0*

X6

9

TC

W0

%

2A

X6

9

TC

|

Pti 0*

X6

9

The current port timeout period applies to

the currently open T

elnet session only

.

When you start another T

elnet session, it

uses the default global port timeout period.

X6

9

= timeout period in seconds. See the

description above.

This variable is applicable only when the

MLC is connected via Ethernet. If the MLC

is connected via RS-232 protocol, only the

global timeout commands apply

, and any

commands involving

X6

9

r

eturn the E13

error response.

V

iew curr

ent port’s timeout period

Esc

0TC

W0TC

|

X6

9

Command/r

esponse table for SIS commands (continued)

Command

ASCII

(T

elnet)

URL Encoded (W

eb)

Response

Additional description

(host to switcher)

(host to switcher)

(switcher to host)