Check for stress on the arms. To do this
loosen the mounting screws (do not remove).
If the arm or the barrel lifts, this indicates
stress on the arm. Adjust the height of the
threaded barrels to reduce or eliminate
any torque or stress that might be caused
by crossed arms or by projector mounting
points with differing heights. It is important to
keep the arms level and as close (low) to the
projector base as possible.

x.

Check that the projector weight is still as
evenly distributed as possible.
Hand tighten the screws until snug.

ATTENTION:

Do not overtighten the

mounting screws as this may damage the
projector. See the projector manual for the
threaded insert torque setting.

f. Lift the projector up to the adjuster plate and

slide it into place. Tighten down the locking and
pivot screws.

3. — Verify the Image Location

a. Connect a power cable to the projector and

turn it on.

b. Verify image size and location by loosening the

PCM 340 pipe adapter plate wing nuts, and
adjust the plate (left-right) to center the image.

TIP: Remember to include the vertical and

horizontal offsets when aligning the projector.
See the projector manual for information

c. When satisfied, tighten down the plate wing

nuts.

ß

Slide and lock the projector onto the

adjuster plate.

Projector

Center Line

Lens

Center Line

Measure the

horizontal offset

INCORRECT CORRECT
Arm not level, causing stress Arm level, no stress
on mounting point on mounting point

Loosen the screw and adjust

the barrel height to reduce torque

on the arms and bracket.

Tighten down all the
mounting screws.

Washer

TIP: Horizontal offset

PoleVault IP Systems • Installation — Stage 1 (Screen and Projector)