NOTE: The installation must conform to national and local building and electrical codes, and

UL requirements. See the device user guides for details.

1. — Install the Mud Rings

NOTE: These devices can be installed using the

supplied mud ring or a wall box. If installing
a box, allow enough depth for the plate, and
the cables. The box should be at least 2.5
inches (6.4 cm) deep to accommodate the
connectors and cables.
If a suitable wall box is already installed, follow

step 2

onwards.

a. Using the mud ring as a template, trace the

inside of the mud ring onto the mounting
surface.

b. Cut out the material within the marked area.
c. Insert the mud ring into the opening. The mud

ring locking arms should fit easily into the
opening. Flip over the mud ring locking arms
and secure with the screws provided.

TIP: Use a level when fitting the mud ring.

Repeat steps a to c for each additional input wall
plate that needs to be installed.

d. At the desired location mark the opening for the

larger MLC 104 IP Plus mud ring.

e. Repeat steps b and c.

û

Insert the PVT mud ring into the wall.

Wall

Wall Mounting

Mud Ring

4.06"

3.75"

Wall Mouting

Bracket

Rotate locking arm

and insert into wall

opening.

Supplied Mudring for

MLC 104 IP Plus

Wall

ü

Features for MLC Mud Ring Installation

PoleVault IP Systems • Installation — Stage 2 (Wallplates and MLC)