— finish installing the pole mount kit, Aux audio input 5 cable, Vga output cable – Extron Electronics PoleVault IP Systems PVS 305SA IP User Manual

Page 40: Rca output cable, Amp audio output to speakers, Control/power cable from mlc 104 ip plus, Voicelift receiver cable, Optional), Paging sensor cable (optional), Vol/mute control

Advertising
background image

3. — Finish installing the Pole Mount Kit

CAUTION: The PoleVault signal transmission method is specific for PVS 305SA IP switchers working

with PVT wallplates.

DO NOT connect the input ports to an MTP system or to an LAN or data

transmission system.

LAN

LAN

L

R

L

R

L

R

AUX AUDIO

INPUT 5

LINE OUT

VOICELIFT

RECEIVER

PAGING

SENSOR

DO NOT

GROUND

OR SHORT

SPEAKER

OUTPUTS

1B RGB

1A RGB

2B RGB

2A RGB

3B RGB

/VIDEO

4B RGB

/VIDEO

3A RGB

4A RGB

I

N
P
U
T
S

RS-232 MLC/IR

2/4/8

Ohms

CLASS 2 WIRING

AMPLIFIED AUDIO OUT

VOL/MUTE

Tx Rx IR

12V

10V

50mA

POWER

RGB

VIDEO

OUTPUTS

CONTROL

N15779

12V
5A MAX

LAN 3

LAN 4

LAN 1

LAN 2

PVT RGB D IP Plus
Video/audio Inputs
(2 CAT 5 cables, A and B
with RJ-45 connectors)

RGB Output
to Projector

External Power Supply
(12 VDC, 5 A max.)

Audio Output
to Speakers

Composite
Video Output
to Projector

PVT CV D Input
(CAT 5 cable with
RJ-45 connector)

MLC 104 IP Plus RS-232 input

10V

Power
Connector

RCA
Connector

VGA
Connector

Aux Audio
Input 5

VoiceLift
Receiver

Paging
Sensor

Vol/Mute
Control

Line Out
Output
(audio)

Red

Positive (+)

Black

Negative (-)

Speaker
wire color

PVS terminal
(left and right)

White

A - (Tx on RS-232 port)

Violet

B - (Rx on RS-232 port)

Drain wire D - Ground ( )
Black

D - Ground ( )

Red

E - +12 V

MLC
wire color

To PVS terminal

4-port 10/100
Ethernet Switch

Connect to ports as follows:
1. TCP/IP network
2. MLC controller
3. PVT RGB D IP Plus RJ-45 pass-through
4. PVT RGB D IP Plus RJ-45 pass-through

3B VIDEO

1A RGB

1B RGB

COMPUTER IN

AUDIO

IN

OUT

MONITOR OUT

IR OUT

S G

CAT5e

CAT5e

AUDIO IN

L

R

VIDEO IN

IR OUT

S G

1

7

6

8

13

10

11

2

4

5

9

3

12

B

A

+12 VDC

Ground ( )

Transmit (Tx)

Receive (Rx)

Ground ( )

LAN pass-through
cables with RJ-45 connectors to
4-port Ethernet switch
inputs 3 and 4 (see )

12

NOTE: The default input signal for the switcher ports 3 and 4 is video. Do not connect an RGB cable

(cable A) to ports 3A and 4A when connecting composite video cables to ports 3B and 4B. If using
VGA inputs for ports 3 or 4, the ports must be reconfigured using the MLS Configuration software utility
on the supplied DVD or at

www.extron.com

.

c

Aux audio input 5 cable

d

VGA output cable

e

RCA output cable

f

Amp audio output to speakers

g

Line out cable to an assistive or recording

device (optional, see audio warning card for
details)

h

Control/power cable from MLC 104 IP Plus

i

VoiceLift Receiver cable

(optional)

j

Paging sensor cable (optional)

k

Vol/Mute control.

l

Pass-through LAN cables as follows:

• Lan 1 - TCP/IP Ethernet
• Lan 2 - MLC controller
• Lan 3 - RGB D IP Plus RJ-45 pass-through
• Lan 4 - RGB D IP Plus RJ-45 pass-through

m

Power supply. Do not apply power yet.

Connect the cables as follows to the switcher:

a

RGB D IP Plus Input wall plate (CAT 5) cables according to the cable labels

b

RGB CV D Input wall plate (CAT 5) cables according to the cable labels

Your completed connections should look like the image below.

PoleVault IP Systems • Installation — Stage 4 (PMK 550 and PVS 305SA IP)

36

Advertising