Command/response table for sis commands, continued – Extron Electronics SW HDMI LC User Guide User Manual

Page 22

Advertising
background image

SW HDMI LC • Remote Communication and Control

16

Command

ASCII Command
(host to unit)

Response
(unit to host)

Additional Description

Request information, part number, and firmware version (continued)

Request part number

N

60-xxxx-01

]

Show the switcher part number:
SW2 HDMI LC: 60-1159-01
SW4 HDMI LC: 60-1160-01

Query firmware version

Q

X%

]

Show the current firmware build number

X%

,

expressed to the second decimal place.

Example:

Q

1.01

]

Query auto-input switch status

72#

Asw

X@

]

Show On or Off status of auto-input switching.
For

X@

:

0 = disabled
1 = enabled

Reset

Reset

E

ZXXX

}

Zpx

]

Reset the switcher to its factory default values.

Upload firmware

Upload firmware

E

Upload

}

...go
Upl

]

Upload a new firmware version from the
computer. “Upl” appears after the upload is
complete.

Command/response Table for SIS commands, Continued