Extron Electronics System 5cr Plus User Manual

Page 31

Advertising
background image

4-3

System 5cccccrrrrr Plus • Serial Communication

The error response codes and their descriptions are as follows:

E01 – Invalid input channel number (the number is too large)
E10 – Invalid command
E13 – Invalid value (the number is out of range/too large)
E16 – Unit is busy
E23 – Checksum error.

Using the command/response tables

The command/response tables on the next page list valid command ASCII codes,
the switcher’s responses to the host, and a description of the command’s function
or the results of executing the command. Lower case characters are acceptable in
the command field only where indicated.

The ASCII to HEX
conversion table at left is
for use with the
command/response tables.

ASCII to HEX Conversion Table

ASCII to Hex conversion table

Advertising