Spencer 4BOB Multistage Centrifugal Blowers User Manual

Page 17

Advertising
background image

1177

IIXX.. TTrroouubblleesshhoooottiinngg G

Guuiiddee

(cont.)

PPRRO

OBBLLEEM

M

PPoossssiibbllee CCaauussee

CCoorrrreeccttiivvee AAccttiioonn

IInnddiiccaattiioonn:: m

maacchhiinnee m

maallffuunnccttiioonn –– iinntteerrnnaall nnooiissee

• Impellers and/or deflectors worn due to age

Correct abrasive conditions if present; replace impellers

or abrasion from dirty air or gas.and/or deflectors.

• Impeller(s) hitting after customer reassembly

Reassemble according to instructions, tighten impellers.

and/or impeller(s) slipping shaft due to heat

Bleed air at low flow to reduce heat. Change inlet

or excessive inlet pressure.

conditions if necessary.

• Machine in surge (see page 8).

Increase airflow.

• Keyed hubs rattling on startup.

Normal condition (loose when cold, tight at operating

temperature).

• Machine running rough, out of balance.

Rebalance and/or clean machine (see next topic

Machine Vibrating).

• Deflector packings rubbing on shaft or

Ignore if audible only when machine is turned by hand. If

impeller hub (will seat themselves if new).

otherwise audible, replace packings.

• Motor not aligned in housing (SOH)

Reassemble and carefully align shaft and motor.

causing impeller to hit.

• Coupling misaligned and/or out of grease

Check alignment; check coupling for wear and replace if

(4BOH & 4BOB).

necessary; relubricate according to instructions.

• Foreign material in machine.

Disassemble machine, inspect and clean. Reassemble

and consider installing filter to prevent clogging.

IInnddiiccaattiioonn:: m

moottoorr m

maallffuunnccttiioonn

• Abnormal hum or whine.

Check motor manufacturerʼs instructions; check voltage

supply and connections.

• Low voltage, motor not up to speed.

Correct improper voltage.

• High voltage (causes noise and burnout).

Correct improper voltage.

• Bearing noise.

See previous instructions for blower bearings.

• Loose part in motor.

Tighten, repair or replace (check motor manufacturer).

• Low frequency.

Correct improper frequency.

IInnddiiccaattiioonn:: m

meecchhaanniiccaall ffaauulltt

• Material buildup on impellers.

Clean impellers, install inlet filter to prevent further buildup.

• Shaft bent.

Consult Spencer Service Department.

• Bearing failure.

Replace bearing(s).

• Unbalanced replacement motor installed.

Balance motor.

• Impeller failure.

Replace impeller(s).

• Motor not aligned in housing (SOH & 4BOH),

Align motor, realign shaft.

impeller rubbing.

• Coupling misaligned (4BOH & 4BOB).

Align coupling.

• Inlet and/or discharge piping connected

Install flexible connectors at inlet and discharge.

to machine without flexible connector,

causing torque or stress on housing.

• Machine bolted down, causing

Remove bolts, use dowel pins or set in guide channels.

misalignment.

• Bearing(s) cramped due to improper fit.

Check bearings, shaft and housing, correct bearing fit.

• Piping not adequately supported.

Anchor piping properly beyond flexible connector.

• Incorrect motor voltage, causing assembly

Check voltage and wiring connections, correct voltage.

to operate at improper speed.

M

MAACCHHIINNEE

NNO

OIISSYY

M

MAACCHHIINNEE

VVIIBBRRAATTIINNG

G

Advertising
This manual is related to the following products: