Electrical wiring, Installation, 2 (black) 3 (white) – Pump Solutions Group PZiG Series User Manual

Page 13: Pulse transmitting flow meter, Pzig

Advertising
background image

12

Installation

Electrical Wiring

Connection to a TACMINA Pulse Transmitting Flow Meter

• Cable w/ 4-pin connector

Bring leads 1 (red) and 3 (white) of the 3-core cable provided with the flow meter together, and connect them to lead

1 (brown) of the cable w/ 4-pin connector on the PZiG.

Connect lead 2 (black) to lead 4 (black) of the same cable w/ 4-pin connector.

• Cable w/ 8-pole connector

Bring leads 1 (red) and 3 (white) of the 3-core cable provided with the flow meter together, and connect them to lead

1 (white) of the cable w/ 8-pin connector on the PZiG.

Connect lead 2 (black) to lead 3 (green) of the same cable w/ 8-pin connector.

* The pump can be connected to multiple flow meters in parallel.

START

STOP

MODE

FUNC

RESET

SET

90

100%

STROKE LENGTH

0

80

20

50

30

40

70

60

ALARM

AUTO

PL

Pulse transmitting flow meter

1 (brown)

1 (red)

4 (black)

Cable w/ 4-pin
connector

PZiG

2 (black)

3 (white)

Pulse Input Signal Specifications
No-voltage pulse or open collector
Input resistance Approx. 2 K

Max. number of pulses 600 pulse/min
Min. pulse width 50 msec (ON time)

START

STOP

MODE

FUNC

RESET

SET

90

100%

STROKE LENGTH

0

80

20

50

30

40

70

60

ALARM

AUTO

PL

To receive pulse inputs by an 8-pin connector, the pump parameters must be changed.
(in the case of default parameter settings)

[How to change parameter settings]

1. Stop pump operation in the manual mode.

2. Hold down the key with the key held down.

3. Display P

-02 by the keys.

4. Press the key and set the parameter number to 0 by the keys.

5. Press the key to apply the setting, and set to the P

-04 display by the keys.

6. Press the key and change the number to 1 by the keys.

7. Press the key to apply the setting, and press the key to return to the previous screen.

Pulse transmitting flow meter

RESET

SET

RESET

SET

RESET

SET

RESET

SET

RESET

SET

FUNC

1 (white)

1 (red)

3 (green)

Cable w/ 8-pin
connector

PZiG

2 (black)

3 (white)

05-45_PZiG Series(2)English 06.8.4 9:39 AM y [ W 12

Advertising