Discharge performance of high-viscosity liquids, Specifications – Pump Solutions Group PZiG Series User Manual

Page 40

Advertising
background image

39

Specifications

Length of Discharge-side Piping

and Discharge Volume

The graph below shows the relationship between piping
length and discharge volume. Installing a damper
lessens piping resistance and allows the length of the
piping to be extended.

PZiG-1300-VTCE-12x18-W-S
Conditions: Room temperature, clean water

Piping length, discharge volume,
and effect of damper

1200

1220

1240

1260

1280

1300

1320

1340

1360

1380

1400

0

2

4

6

8

10

12

Piping length (m)

Discharge volume [mL/min]

with a
damper

without a
damper

* Discharge pressure 0.20 MPa

Discharge Performance of

High-viscosity Liquids

When a fast stroke speed is set for transferring high-
viscosity liquids, piping resistance on the suction side
may cause the amount of sucked in liquid to be
reduced.

PZiG-300-VTCF-VP20-V-S
Conditions: Room temperature

0

50

100

150

200

250

300

350

400

0

100

200

300

Strokes (spm)

Discharge volume [mL/min]

Polymer
coagulants
(1000mPa . S)

Clean water

* Discharge pressure 1.0 MPa