For the safe use of this product – Pump Solutions Group PZiG Series User Manual

Page 2

Advertising
background image

1

*1 The ambient temperature

range is -10°C to 50°C during
transportation and storage.
Also, do not subject this
pump to strong shock during
transportation and storage.

*2 Install the chemical tank

at a location higher than
the pump using pressure
boosting piping.

Also, note that the viscosity
that can be transferred and
the discharge volume change
according to piping conditions
and the nature of chemicals.

Transportation, Installation & Piping

¡This pump is not made to explosion-proof specifications. Do not install this pump in explosion-proof areas or in

explosive/inflammable atmospheres.

¡Install this pump in a location where it will not come into contact with other people besides the operator.
¡Reliably ground the ground terminal. Failure to do so might cause electric shock.

¡Connect the piping to the pump correctly.
¡If this pump is dropped or becomes damaged, contact us or your supplying agent. Continued use of this pump

might cause an accident or damage.

TACMINA Europe Representative Office

Hochstr.35,56235 Ransbach-Baumbach,Germany
Tel.+49(0)2623-928-345 Fax.+49(0)2623-928-507 E-mail:[email protected]

¡Do not install this pump at humid or dusty location. Doing so might cause electric shock or malfunction.
¡Be sure to connect and wire the ground lead (green) to prevent electric shock.

!

CAUTION

!

WARNING

Conditions of Use

¡This pump cannot be used in explosion-proof areas, and in explosive/ignitable atmospheres.

¡This pump can be used for injection of chemicals only. Do not use this pump for other applications. Doing so

might cause accidents or malfunction.

¡This pump cannot be used for transferring fluids that contain slurry.
¡The discharge volume cannot be adjusted by operating valves on the discharge piping.
¡This pump generates pulsation. Install a pulsation attenuator such as a damper.
¡Do not use this pump outside the operating ranges indicated below. Doing so might cause malfunction.

!

CAUTION

!

WARNING

For the Safe Use of This Product

This User's Manual is intended to help the operator to handle the product safely and correctly. In support of this aim,
important safety-related instructions are classified as explained below.
Be sure to follow them at all times.

¡If the product is operated incorrectly in contravention of this instruction, it is possible that an accident

resulting in death of serious injury will occur.

¡This indicates that improper operation can result in an injury or physical damage to the product.

¡This indicates information that should always be followed to maximize the product's performance and service

life.

¡This indicates supplementary explanations.

NOTE

IMPORTANT

!

CAUTION

!

WARNING

Ambient temperature

0 to 40°C*

1

Operating liquid temperature

0 to 40°C (freezing not allowed)

Viscosity

Standard valve type

50 mPa • s or less

1000 mPa • s or less

PZiG-300

1.0 MPa (0.5 MPa on the FTCT type with PTFE tube)

0.2 MPa

Installation location 1000 m above sea level or less

Max. discharge pressure

High-viscosity valve type*

2

PZiG-1300

PZiG-500

0.7 MPa (0.5 MPa on the FTCT type with PTFE tube)

PZiG-700

0.4 MPa

PZiG-1000

0.3 MPa

Humidity

35 to 85% (freezing not allowed)

01-04_PZiG Series(2)English 06.8.4 9:19 AM y [ W 1

Advertising